Error Condition Head Open

Error Condition Head Element Bad

Warning Ribbon In

Warning Head Too Hot

76

Brady X-PLUS Series User’s Guide

Problem

Solution

The printhead is not fully closed.

Close the printhead.

Problem

Solution

One or more of the printhead elements

have failed the printhead element test.

If the failed elements impact your printing application,

replace the printhead. To override this error, disable

the head test count feature on the front panel by

defaulting the value to “0000.” See page 59.

Problem

Solution

The ribbon is loaded.

Remove the ribbon and set the printer to direct thermal

mode.
Ensure that the printer driver and/or software settings

are correctly set (if applicable).

Problem

Solution

The printhead is over temperature.

Allow the printer to cool. Printing automatically

resumes when the printhead elements cool to an

acceptable operating temperature.