beautypg.com

3 input locking, Input locking, Input menu – Barco CLM R10+ User Manual

Page 69

background image

8. Input menu

Input
module

Indication

Description

RGB SOG

RGB input with sync on green

YUV HS/VS - CS

Component video with separate horizontal and vertical sync or separate composite
sync.

YUV CV

Component video with composite video as sync signal

YUV SOY

Component video with sync on Y

CVBS

Composite video

S-Video

Super video

INP 1 PRIORITY

When signal on both inputs, input 1 has the priority.

INP 2 PRIORITY

When signal on both inputs, input 2 has the priority.

INP1

Input 1 selected

HD-SDI -
SDI

INP2

Input 2 selected

DVI HDCP

DVI HDCP

High definition content protected DVI input

DVI equalization

When a standard DVI module is selected, press ENTER to go in edit mode. Use or to key to change the equalization value.

Default value = 13.

For non DVI-compliant transmitter, stronger equalization may be necessary even for shorter cables.

For longer cables adjust between 0 and 13 (more equalization).

For shorter cables adjust between 13 and 15 (least equalization).

Advanced settings for 5 cable input

For RGB with separate sync or YUV with separate sync the sync level can be toggled between Analog or Digital.

Use the ▲ or ▼ key to select Advanced settings. The 5 cable advanced box opens.

Press ENTER to toggle between Analog or Digital.

Image 8-5

8.3

Input locking

What is possible?

The output signal can be locked on an internal sync signal or on the sync signal of one of the input sources. Input locking can avoid
that some windows in the output signal are slowly moving or trembling.

When automatic is selected, the lock will be set on the input signal of the main window.

How to set up?

1. Press MENU to activate the menus.

2. Use the ▲ or ▼ key to select Input and press ENTER.

The Input menu is displayed.

3. Use the ▲ or ▼ key to select Input locking and press ENTER.

The input locking window is displayed. The actual selected locking method is indicated by an arrow.

4. Use the ▲ or ▼ key to select the desired locking and press ENTER. (image 8-6, image 8-7, image 8-8)

R59770021 CLM R10+ 11/10/2010