E. troubleshooting, E.1 error codes, Error codes – Barco CLM R10+ User Manual
Page 207
E. Troubleshooting
E. TROUBLESHOOTING
E.1 Error codes
Overview
When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.
When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description
Error
Warning
Caused by
Action
1001
Wrong lamp 1
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a qualified service engineer
1002
Wrong lamp 2
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a qualified service engineer
1003
Wrong lamp 3
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a qualified service engineer
1004
Wrong lamp 4
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a qualified service engineer
1011
Lamp 1 missing
Yes
Yes
No lamp inserted in position 1
Insert a lamp in position 1
1012
Lamp 2 missing
Yes
Yes
No lamp inserted in position 2
Insert a lamp in position 2
1013
Lamp 3 missing
Yes
Yes
No lamp inserted in position 3
Insert a lamp in position 3
1014
Lamp 4 missing
Yes
Yes
No lamp inserted in position 4
Insert a lamp in position 4
1021
Lamp 1 broken
Yes
-
Lamp 1 is not ON
Check installation of lamp 1
(connection, cable, etc.)
1022
Lamp 2 broken
Yes
-
Lamp 2 is not ON
Check installation of lamp 2
(connection, cable, etc.)
1023
Lamp 3 broken
Yes
-
Lamp 3 is not ON
Check installation of lamp 3
(connection, cable, etc.)
1024
Lamp 4 broken
Yes
-
Lamp 4 is not ON
Check installation of lamp 4
(connection, cable, etc.)
1399
I²C open error
Yes
1398
I²C read error
Yes
1397
I²C write error
Yes
1699
Formatter busy
1697
Formatter init
failed
Yes
-
no communication with formatter
ctrl
Call a qualified service engineer
1696
Formatter ctrl
init failed
Yes
-
no communication with formatter
ctrl
Call a qualified service engineer
1695
Formatter start
failed
Yes
-
no communication with formatter
Call a qualified service engineer
1693
1692
1691
2100
LPS 1 error
Yes
-
Replace LPS
2400
LPS 2 error
Yes
-
Replace LPS
2700
LPS 3 error
Yes
-
Replace LPS
3000
LPS 4 error
Yes
-
Replace LPS
R59770021 CLM R10+ 11/10/2010