E. troubleshooting – Barco CLM R10+ User Manual
Page 209
E. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
7908
Fan inlet A low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7906
Fan inlet B low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7904
Fan lamp 1
back low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7902
Fan lamp 2
back low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7900
Fan lamp 3
back low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7899
Fan lamp 3
back high
-
Yes
7898
Fan lamp 4
back low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7896
Fan prism low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7894
Fan color
wheel low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7892
Fan lamp 1
front low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7890
Fan lamp 2
front low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7888
Fan lamp 3
front low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7886
Fan lamp 4
front low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a qualified
service engineer
7884
Pump speed
low
Yes
Yes
Bad or no water flow in the cooling
circuit
If problem persists, call a qualified
service engineer
7883
Pump speed
high
-
Yes
Ignore this message
7878
Over temp
Yes
Yes
extreme overheading of DMD or
lamps
If problem persists, call a qualified
service engineer
7877
Under temp
DMD too cold
Warm up the projector
7876
SMPS input
range
Supplied voltage is out of range
Check supplied voltage range
7875
DMD temp
open
Yes
Yes
Sensor not connected
If problem persists, call a qualified
service engineer
7874
DMD temp
short
Yes
Yes
short circuit in sensor circuit
If problem persists, call a qualified
service engineer
7873
Ambient temp
open
Yes
Yes
Sensor not connected
If problem persists, call a qualified
service engineer
7872
Ambient temp
short
Yes
Yes
short circuit in sensor circuit
If problem persists, call a qualified
service engineer
7871
TEC temp open
Yes
Yes
Sensor not connected
If problem persists, call a qualified
service engineer
7870
TEC temp short
Yes
Yes
short circuit in sensor circuit
If problem persists, call a qualified
service engineer
7865
Lamp 1 run
time msg
exceeded
-
Yes
Run time of lamp 1 will be exceeded
Replace the lamp with a new one.
Call a qualified service engineer
7864
Lamp 1 run
time warning
exceeded
-
Yes
Run time of lamp 1 is exceeded
Replace the lamp with a new one.
Call a qualified service engineer
7863
Lamp 1 run
time max
exceeded
-
Yes
The maximum run time for the lamp
is exceeded
Replace the lamp with a new one.
Call a qualified service engineer
R59770021 CLM R10+ 11/10/2010