FACTORY OPTIONS AND/OR ACCESSORIES

Economizer (dry--bulb or enthalpy)

Economizers save money. They bring in fresh, outside air

for ventilation; and provide cool, outside air to cool your

building. This is the preferred method of low--ambient

cooling. When coupled to CO

2

sensors, Economizers can

provide even more savings by coupling the ventilation air

to only that amount required.

Economizers are available, installed and tested by the

factory, with either enthalpy or dry--bulb temperature

inputs. There are also models for electromechanical as

well as direct digital controllers. Additional sensors are

available as accessories to optimize the economizers.

CO

2

Sensor

Improves productivity and saves money by working with

the economizer to intake only the correct amount of

outside air for ventilation. As occupants fill your building,

the CO

2

sensor detects their presence through increasing

CO

2

levels, and opens the economizer appropriately.

When the occupants leave, the CO

2

levels decrease, and

the sensor appropriately closes the economizer. This

intelligent control of the ventilation air , called Demand

Control Ventilation (DCV) reduces the overall load on the

rooftop, saving money.

Smoke Detectors

Trust the experts. Smoke detectors make your application

safer and your job easier. Bryant’s smoke detectors

immediately shut down the rooftop unit when smoke is

detected. They are available, installed by the factory, for

supply air, return air, or both.

Louvered Hail Guards

Sleek, louvered panels protect the condenser coil from

hail damage, foreign objects, and incidental contact.

Convenience Outlet (powered or un--powered)

Lower service bills by including a convenience outlet in

your specification. Bryant will install this service feature

at our factory, powered. Provides a convenient, 15 amp,

115v GFCI receptacle.

Non--fused Disconnect

This OSHA--compliant, factory--installed, safety switch

allows a service technician to locally secure power to the

rooftop.

Barometric Relief

Gravity controlled, barometric relief equalizes building

pressure and ambient air pressures. This can be a cast

effective solution to prevent building pressurization.

Power Exhaust with Barometric Relief.

Superior internal building pressure control. This

field--installed accessory may eliminate the need for

costly, external pressure control fans.

RTU--MP, Multi--protocol Controller

Connect the rooftop to an existing BAS without needing

complicated translators or adapter modules using the

RTU--MP controller. This new controller speaks the 4

most common building automation system languages

(Bacnet, Modbus, N2, and Lonworks). Use this controller

when you have an existing BAS.

Time Guard II Control Circuit

This accessory protects your compressor by preventing

short--cycling in the event of some other failure, prevents

the compressor from restarting for 30 seconds after

stopping. Not required with PC, RTU--MP, or authorized

commercial thermostats.

Filter or Fan Status Switches

Use these differential pressure switches to detect a filter

clog or indoor fan motor failure. When used in

conjunction with a compatible unit controller/thermostat,

the switches will activate an alarm to warn the appropriate

personnel.

Motorized 2--Position Damper

Bryant’s new, 2--position, motorized outdoor air damper

admits up to 100% outside air. Using reliable, gear--driven

technology, the 2--position damper opens to allow

ventilation air and closes when the rooftop stops, stopping

unwanted infiltration.

Manual OA Damper

Manual outdoor air dampers are an economical way to

bring in ventilation air.

Motormaster Head Pressure Controller

The Motormaster motor controller is a low ambient, head

pressure controller kit that is designed to maintain the

unit’s condenser head pressure during periods of low

ambient cooling operation. This device should be used as

an alternative to economizer free cooling not when

economizer usage is either not appropriate or desired. The

Motormaster will either cycle the outdoor--fan motors or

operate them at reduced speed to maintain the unit

operation, depending on the model.

Winter Start Kit

Bryant’s winter start kit extends the low ambient limit of

your rooftop to 25_F (--9_C). The kit bypasses the low

pressure switch, preventing nuisance tripping of the low

pressure switch. Other low ambient precautions may still

be prudent.

UV--C Lights

Bryant’s commercial rooftop ultra--violet germicidal

lamps are designed to kill odor causing mold and fungus

that may develop in the cool and damp evaporator section

of an HVAC unit. The high output, low temperature

germicidal lamps are installed in the evaporator section of

the HVAC unit, and shine directly on the evaporator coil

558J