beautypg.com

Bryant LEGACY 558J User Manual

Page 2

background image

2

TABLE OF CONTENTS

PAGE

FEATURES AND BENEFITS

3

. . . . . . . . . . . . . . . . . . . .

MODEL NUMBER NOMENCLATURE

4

. . . . . . . . . . . .

FACTORY OPTIONS & ACCESSORIES

5

. . . . . . . . . . .

ARI CAPACITY RATING

8

. . . . . . . . . . . . . . . . . . . . . . .

SOUND PERFORMANCE

10

. . . . . . . . . . . . . . . . . . . . . .

PHYSICAL DATA

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BASE UNIT DIMENSIONS

16

. . . . . . . . . . . . . . . . . . . . .

APPLICATION DATA

18

. . . . . . . . . . . . . . . . . . . . . . . . .

PAGE

COOLING TABLES

20

. . . . . . . . . . . . . . . . . . . . . . . . . . .

STATIC PRESSURE TABLES

24

. . . . . . . . . . . . . . . . . . .

FAN PERFORMANCE

25

. . . . . . . . . . . . . . . . . . . . . . . . .

OUTDOOR AIR INTAKE & EXHAUST PERF

33

. . . . .

ELECTRICAL INFO

34

. . . . . . . . . . . . . . . . . . . . . . . . . . .

MCA / MOCP

36

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TYPICAL WIRING DIAGRAM

45

. . . . . . . . . . . . . . . . . .

GUIDE SPECIFICATIONS

47

. . . . . . . . . . . . . . . . . . . . . .

Your Bryant rooftop unit (RTU) was designed by customers for customers. With “no--strip” screw collars, handled access

panels, and more we’ve made your unit easy to install, easy to maintain, easy to use, and easy to love.

Easy to install:

All 558J units are horizontal. No special adapter curbs are necessary. Convertible airflow design makes it easy to adjust to

unexpected job--site complications. Lighter units make easy replacement. Bryant 3--6 ton 558J rooftops fit on existing

Bryant curbs. Also, our large control box gives you room to work and room to mount Bryant accessory controls.

Easy to maintain:

Bryant’s easy access handles provide quick and easy access to all normally serviced components. Our “no--strip” screw

system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s

metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite

plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Now, you can take

refrigeration system pressure readings without affecting the condenser airflow.

Easy to use:

Bryant rooftops have high and low pressure switches, a filter drier, and 2” filters standard. Bryant’s terminal board puts all

your connections and troubleshooting points in one place, standard. Most low voltage connections are made to the same

board and make it easy to find what you’re looking for and easy to access it.