Save Configuration

Save the configuration to flash memory. If the switch is powered off without

saving the configuration, all changed configuration will lost

„ Click

Save Flash

Save Configuration Interface

Rate Control

Set up each port’s bandwidth rate and packet limitation type

„ Limit Packet type: Select the packet type to filter. The packet filter

types are all packet types, broadcast/multicast/unknown, unicast

packets, broadcast/multicast packets, and broadcast packet only. The

broadcast/multicast/unknown, unicast packet, broadcast/multicast

packet, and broadcast packet only are only for ingress. The egress rate

only supports all packet types.

„ Ports 1 through 5 support port ingress and egress rate control. For

example, assume port 1 is 10Mbps, users can set its effective egress

rate to 1Mbps, and the ingress rate to 500Kbps.

¾ Ingress: Select the port effective ingress rate. The valid range

value is 1MB, 2MB, 4MB, 8MB, 16MB, 32MB and 64MB. The

default value is “disable”

¾ Egress: Select the port effective ingress rate. The valid range

value is 128kbps, 256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB.

The default value is “disable”

„ Click

Apply