EIR505 Series-5107qsg

International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA

815-433-5100 Fax 433-5104

www.bb-elec.com

[email protected]

[email protected]

European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland

+353 91 792444 Fax +353 91 792445

www.bb-europe

.com [email protected] [email protected]

Quick Start Guide

Elinx Managed Ethernet Switch

EIR505 Series

Items Included

1

2

Default Settings

3

DIP Switch Settings

4

LED Chart

5

Hardware Installation














o

Ethernet Switch

o

CD with Support Manual

o

This Quick Start Guide

o

Panel Mount Bracket


o

IP Address: 192.168.16.1

o

Subnet Mask: 255.255.255.0

o

Gateway: 192.168.15.254

o

User Name: root, Password: root














o

Record the switch’s MAC Address in the space
provided. The MAC Address is printed on the product
label. Provide the MAC Address to your Network
Administrator. The Network Administrator should
provide an IP Address, Subnet Mask, and Gateway.

o

Select a mounting location and install with the attached
DIN rail clip or included panel mount kit.

o

Connect power to the switch

o

12 to 48 VDC

o

Redundant DC input is available with fault
contacts.


Pos

Status Description
OFF

Disable port 1 Alarm

1

ON

Enable port 1 Alarm
(If port 1 link fails, the fault LED will light)

OFF

Disable port 2 Alarm

2

ON

Enable port 2 Alarm
(If port 2 link fails, the fault LED will light)

OFF

Disable port 3 Alarm

3

ON

Enable port 3 Alarm
(If port 3 link fails, the fault LED will light)

OFF

Disable port 4 Alarm

4

ON

Enable port 4 Alarm
(If port 4 link fails, the fault LED will light)

OFF

Disable port 5 Alarm

5

ON

Enable port 5 Alarm
(If port 5 link fails, the fault LED will light)

OFF

Disable the ring master function

6

ON

Enable the switch as the ring master
in the redundant ring group.




LED Status

Meaning

Green

The switch is powered on

Power

Off

The switch is powered off

R.M.

Green

Ring Master (Master of a Redundant Ring)

(Ring Master) Off

The switch is not a Ring Master

Green

Power Source 1 is available

Power 1

Off

Power Source 1 is unavailable

Green

Power Source 2 is available

Power 2

Off

Power Source 2 is unavailable

Yellow

Power Source Failure or Port Failure

Fault

Off Normal

Operation

Green

The port is linked

Blinking

The port is receiving or transmitting packets

Link/ACT

Port 5

Off

No device attached

Yellow

Full Duplex Mode

Blinking Data

Collision

FDX/COL

Port 5

Off

Half Duplex Mode