beautypg.com

B&B Electronics EIR505-XX User Manual

Page 50

background image

40

Manual Documentation Number: EIR505-xx_5107m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

ring master has the rights to negotiate and place a command to other

switches in the X-Ring group. If more than one switch is in master mode,

the software will select the switch with lowest MAC address number as the

ring master. An LED on the front panel indicates that the switch is the ring

master.

Coupling ring is used to connect 2 or more X-Ring groups providing a

redundant back-up Dual homing is used to recover from a connection loss

between an X-Ring group and the upper level/core switch.

„ Enable X-Ring: Mark the check box to enable the X-Ring function

„ 1

st

& 2

nd

Working Ports: Assign two ports as the member ports. One

port will be working port and one port will be the backup port. The

system will automatically decide which port is working port and which

port is backup port

„ Enable Coupling Ring: Mark the check box to enable the coupling

ring function

„ Coupling port: Assign the member port

„ X-Ring Master: Set the switch labeled RM on front panel to on position.

This establishes that switch as a master for the ring.

„ Enable Dual Homing: Set up one of port to be the Dual Homing port.

In an X-Ring group, only one can be a Dual Homing port. This function

will only work when the X-Ring function is enabled

„ Click

Apply