Cleaning the paper pick-up rollers, Calibration, Cleaning the paper pick-up rollers calibration – Brother DCP-9010CN User Manual
Page 83: Ccleaning the paper pick-up rollers

Troubleshooting and routine maintenance
75
C
Cleaning the paper pick-up
rollers
C
If you have paper feed problems, clean the
paper pick-up rollers as follows:
a
Turn off the machine. Unplug the power
cord from the electrical socket.
b
Pull the paper tray completely out of the
machine.
c
Tightly wring out a lint-free cloth soaked
in lukewarm water, and then wipe the
separator pad (1) of the paper tray with
it to remove dust.
d
Wipe the two pick-up rollers (1) inside of
the machine to remove dust.
e
Put the paper tray back in the machine.
f
Plug the machine’s power cord back into
the electrical socket. Turn on the
machine.
Calibration
C
The output density for each colour may vary
depending on the environment the machine is
in such as temperature and humidity.
Calibration helps you to improve the colour
density.
a
Press Menu, 3, 5.
b
Press a or b to select Calibrate.
c
Press OK.
d
Press 1 to select Yes.
e
Press Stop/Exit.
You can reset the calibration parameters
back to those set at the factory.
a
Press Menu, 3, 5.
b
Press a or b to Reset.
c
Press OK.
d
Press 1 to select Yes.
1
1