17 tcp/ip setting function, 1 setting the ip address, From the control panel – Konica Minolta bizhub 751 User Manual
Page 118: Tcp/ip setting function -102
751/601
2-102
Administrator Operations
2
2.17
TCP/IP Setting Function
When access to the Administrator of the machine by the Administrator Settings is authenticated, the machine
enables setting of the IP Address and registration of the DNS Server.
2.17.1
Setting the IP Address
2
Note
Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If
it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings.
0
For the procedure to call the Network Settings menu to the display, see steps 1 and 2 of
the auth-password and priv-password" on page 2-94
.
1
Call the Network Settings to the screen from the control panel.
2
Touch [TCP/IP Settings].
3
Touch [IP Settings].
4
Touch [Manual Input].
5
Select [IP Address] and set the IP Address.
–
If [Auto Input] has been selected for IP Application Method in step 4, select the means of acquiring
the IP Address automatically from among DHCP Settings, BOOTP Settings, ARP/PING Settings,
AUTO IP Settings, and the like.
6
Touch [OK].
0
For the procedure to call the Network menu to the display, see steps 1 and 2 of
password and priv-password" on page 2-94
.
1
Start the PageScope Web Connection and call the Network menu to the display.
2
Click the [TCP/IP Setting] menu.
3
Select [Manual Setting] from the IP Address Setting Method pull-down menu.
4
Enter the IP Address in the "IP Address" box.
–
If [Auto Setting] is selected from the IP Address Setting Method pull-down menu in step 3, select
the means with which to acquire the IP Address automatically, including DHCP, BOOTP, ARP/PING,
and AUTOIP setting.
5
Click the [OK].
6
Click the [OK].
7