21 tcp/ip setting function, 1 setting the ip address, Tcp/ip setting function -102 – Konica Minolta bizhub C364 User Manual
Page 118: Setting the ip address -102
bizhub C554/C454/C364/C284/C224
2-102
2.21
TCP/IP Setting Function
2
2.21
TCP/IP Setting Function
When access to the machine by the administrator of the machine through the Administrator Settings is au-
thenticated, the machine enables setting of the IP Address and registration of the DNS Server.
2.21.1
Setting the IP Address
0
For the procedure to call the Network Settings screen on the display, see steps 1 and 2 of page 2-87.
0
Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If
it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings.
1
Call the Network Settings screen on the display from the control panel.
2
Touch [TCP/IP Settings].
3
Touch [IPv4 Settings].
4
Touch [Manual Input].
5
Select [IP Address] and set the IP Address.
% If [Auto Input] is selected for IP Application Method in step 4, select the means of acquiring the IP
Address automatically from among DHCP Settings, BOOTP Settings, ARP/PING Settings, AUTO IP
Settings, and the like.
6
Touch [OK].
7
Touch [OK].
% If a message appears that prompts you to turn OFF and ON the main power switch, turn OFF and
ON the main power switch. When the main power switch is turned off, then on again, wait at least
10 seconds to turn it on after turning it off. If there is no wait period between turning the main power
switch off, then on again, the machine may not function properly.
Here is the sequence, through which the main power switch and sub power key are turned on and
off:
Turn off the sub power key ö Turn off the main power switch ö Turn on the main power switch ö
Turn on the sub power key
0
For the procedure to access the Admin Mode, see page 2-2.
0
Do not leave the machine with the Admin Mode setting screen left shown on the display. If it is abso-
lutely necessary to leave the machine, be sure first to log off from the Admin Mode.
1
Start PageScope Web Connection and access the Admin Mode.
2
Click the [Network] tab.
3
Click [TCP/IP Setting] ö [TCP/IP Setting] from the menu.
4
Select [Manual Setting] from the IP Address Setting Method pull-down menu.
5
Enter the IP Address in the "IP Address" box.
% If [Auto Setting] is selected from the IP Address Setting Method pull-down menu in step 4, select
the means with which to acquire the IP Address automatically, including DHCP, BootP, ARP/PING,
and Auto IP setting, and click the check box.
6
Click [OK].