beautypg.com

Nugget 500 series valves – Norgren 500 Series Nugget User Manual

Page 22

background image

Nugget 500 Series Valves

VAL-11-22

Littleton, CO USA

Phone: 303-794-2611

www.norgren.com

Type & Family

Basic Size

Internal Variations

Mounting

Port Size

Thread Type

Secondary Operator 1 2 End

Primary Operator 1 4 End

Operator Description

Solenoid Override/
Pilot Supply

Coil Voltage/Wattage

Electrical Connector

M = Bonded Spool Valve

N = Nugget 500, Cv = 5.0

01 = 5-Port/2-Position, Single Pressure Valve
02 = 5-port/2-Position, Dual Pressure Valve
03 = 5 Port/3-Position, Single Pressure Valve, Spring Centered, All Ports Blocked
04 = 5 Port/3-Position, Dual Pressure Valve, Spring Centered, All Ports Blocked
05 = 5-Port/3-Position, Single Pressure Valve, Spring Centered, Cylinder Open to Exhaust
06 = 5-Port/3-Position, Dual Pressure Valve, Spring Centered, Cylinder Open to Exhaust

C = 5-Port,

Inline Valve

D = 5-Port, Subbase Valve

Without Subbase

E = 5-Port Subbase Valve

Assembled to a Single
Subbase

G = 5-Port, Subbase

Valve Assembled to a
Manifolding Subbase

A = PTF
G = ISO

3 = Air Pilot
5 = Solenoid Pilot

Position

1 2 3 4 5 6 7

8 9

10 11 12 13

1

2

3

4

5

6

7

8

9

10

11

12

13

Valve Body

Operator Description

0 = Use for Air Operator

Operators

= Product Number

3.5 Watt, Nominal

J = 120V/60Hz-110V/50 Hz, 3.5 Watt
L = 24V/60Hz/50z, 3.5 Watt
M = 6VDC, 2 Watt
N = 12 VDC, 2 Watt
P = 24 VDC, 2 Watt
S = 110 VDC, 3.4 Watt

A = Cable Grip
B = Cable Grip with Indicator Light 110/120 VAC/DC
C = 1/2" NPT Conduit
D = 5-ft Molded Cable 0-220 VAC/DC
E = 5-ft Molded Cable with Indicator Light and Surge Suppression, 24 VAC/DC
G = 5-ft Molded Cable with Indicator Light and Surge Suppression, 110 VAC/DC
H = 5-ft Molded Cable with Indicator Light and Surge Suppression, 240 VAC/DC
J = Cable Grip with Indicator Light, 24 VAC/DC
X = Solenoid Without Connector

F = 3/8"
G = 1/2"

F = 3/8"
G = 1/2"
H = 3/4" (PTF only)

1 = Integral Air Return
2 = Same as Primary Operator
3 = Spring Return
7 = Air-Assisted Spring Return

A = Nondetent
B = Detent
F = Spring Centered

0 = Use for Air Operator

7.5 Watt, Nominal

N = No Override, Internal Pilot
P = No Override, External Pilot
R = Non-Locking Override, Internal Pilot
S = Non-Locking Override, External Pilot
T = Locking Override, Internal Pilot
V = Locking Override, External Pilot

7.5 Watt, Nominal

T = 120V/60Hz-110V/50Hz, 7.5 Watt
V = 240V/60Hz-220V/50Hz, 7.5 Watt
W = 24V/60Hz/50Hz, 7.5 Watt
Z = 12 VDC, 7.5 Watt
1 = 24 VDC, 6.0 Watt

3.5 Watt, Nominal

G = No Override, Internal Pilot
H = No Override, External Pilot
J = Non-Locking Override, Internal Pilot
K = Non-Locking Override, External Pilot
L = Locking Override, Internal Pilot
M = Locking Override, External Pilot

0 = Subbase Valve

Without Subbase

0 = Use for Air Operator