Nugget 500 series valves – Norgren 500 Series Nugget User Manual
Page 22
Nugget 500 Series Valves
VAL-11-22
Littleton, CO USA
Phone: 303-794-2611
www.norgren.com
Type & Family
Basic Size
Internal Variations
Mounting
Port Size
Thread Type
Secondary Operator 1 2 End
Primary Operator 1 4 End
Operator Description
Solenoid Override/
Pilot Supply
Coil Voltage/Wattage
Electrical Connector
M = Bonded Spool Valve
N = Nugget 500, Cv = 5.0
01 = 5-Port/2-Position, Single Pressure Valve
02 = 5-port/2-Position, Dual Pressure Valve
03 = 5 Port/3-Position, Single Pressure Valve, Spring Centered, All Ports Blocked
04 = 5 Port/3-Position, Dual Pressure Valve, Spring Centered, All Ports Blocked
05 = 5-Port/3-Position, Single Pressure Valve, Spring Centered, Cylinder Open to Exhaust
06 = 5-Port/3-Position, Dual Pressure Valve, Spring Centered, Cylinder Open to Exhaust
C = 5-Port,
Inline Valve
D = 5-Port, Subbase Valve
Without Subbase
E = 5-Port Subbase Valve
Assembled to a Single
Subbase
G = 5-Port, Subbase
Valve Assembled to a
Manifolding Subbase
A = PTF
G = ISO
3 = Air Pilot
5 = Solenoid Pilot
Position
1 2 3 4 5 6 7
8 9
10 11 12 13
1
2
3
4
5
6
7
8
9
10
11
12
13
Valve Body
Operator Description
0 = Use for Air Operator
Operators
= Product Number
3.5 Watt, Nominal
J = 120V/60Hz-110V/50 Hz, 3.5 Watt
L = 24V/60Hz/50z, 3.5 Watt
M = 6VDC, 2 Watt
N = 12 VDC, 2 Watt
P = 24 VDC, 2 Watt
S = 110 VDC, 3.4 Watt
A = Cable Grip
B = Cable Grip with Indicator Light 110/120 VAC/DC
C = 1/2" NPT Conduit
D = 5-ft Molded Cable 0-220 VAC/DC
E = 5-ft Molded Cable with Indicator Light and Surge Suppression, 24 VAC/DC
G = 5-ft Molded Cable with Indicator Light and Surge Suppression, 110 VAC/DC
H = 5-ft Molded Cable with Indicator Light and Surge Suppression, 240 VAC/DC
J = Cable Grip with Indicator Light, 24 VAC/DC
X = Solenoid Without Connector
F = 3/8"
G = 1/2"
F = 3/8"
G = 1/2"
H = 3/4" (PTF only)
1 = Integral Air Return
2 = Same as Primary Operator
3 = Spring Return
7 = Air-Assisted Spring Return
A = Nondetent
B = Detent
F = Spring Centered
0 = Use for Air Operator
7.5 Watt, Nominal
N = No Override, Internal Pilot
P = No Override, External Pilot
R = Non-Locking Override, Internal Pilot
S = Non-Locking Override, External Pilot
T = Locking Override, Internal Pilot
V = Locking Override, External Pilot
7.5 Watt, Nominal
T = 120V/60Hz-110V/50Hz, 7.5 Watt
V = 240V/60Hz-220V/50Hz, 7.5 Watt
W = 24V/60Hz/50Hz, 7.5 Watt
Z = 12 VDC, 7.5 Watt
1 = 24 VDC, 6.0 Watt
3.5 Watt, Nominal
G = No Override, Internal Pilot
H = No Override, External Pilot
J = Non-Locking Override, Internal Pilot
K = Non-Locking Override, External Pilot
L = Locking Override, Internal Pilot
M = Locking Override, External Pilot
—
—
0 = Subbase Valve
Without Subbase
0 = Use for Air Operator