Specifications

Model IS-20-S, IS-21-S, IS-20-F, IS-21-F, IS-20-H

„

Model IS-2X-F, IS-20-H with

field case

R

A

≤ (U+ – 11 V) / 0.02 A

Test circuit signal and maximum

load

RA

≤ 15 (only model IS-2X-F, IS-20-H with field case)

Adjustability zero/span

%

± 5 using potentiometers inside the instrument

Response time (10 ... 90 %)

ms

1

4)

4)

Response time IS-20-S/-F:

10 ms at medium temp. below < -30 °C for

pressure ranges up to 25 bar.

Response time IS-21:

≤ 10 ms at medium temp. below < -30 °C (-22 °F).

Power Pi

W

1 (750 mW with approval for Category 1D)

Insulation voltage

Insulation complies with EN 60079-11

Accuracy

% of span

0.5

6)

{0.25}

5) 6)

5)

Accuracy { } for pressure ranges

≥ 0.25 bar, not for IS-20-H

6)

Including non-linearity, hysteresis, zero point and full scale error (corresponds to

error of measurement per IEC 61298-2).

Adjusted in vertical mounting position with lower pressure connection.

Non-linearity

% of span

0.2

(BFSL) according to IEC 61298-2

Non-repeatability

% of span

0.1

1-year stability

% of span

0.2

(at reference conditions)

Permissible temperature of

„

Medium

8)

*

)

-20 ... +80 °C

7)

-4 ... +176 °F

7)

(Extended temperature ranges see chapter 7 „Relation of medium

temperature to ambience temperature“)

7)

„

Ambience

8)

-20 ... +80 °C

7)

-4 ... +176 °F

7)

„

Storage

-30 ... +105 °C

-22 ... +221 °F

7)

Other temperature ranges are possible, depending on the electrical connection;

see EC-type examination certificate, e.g. -30 ... +105 °C / -22 ... +221 °F and

table page 83 and 84

Rated temperature range

0 ... +80 °C

32 ... +176 °F

Temperature coefficients within

rated temperature range

Specifications

Model IS-20-S, IS-21-S, IS-20-F, IS-21-F, IS-20-H

„

Mean TC of zero

% of span

0.2 / 10 K (< 0.4 for pressure range

250 mbar)

„

Mean TC of range

% of span

0.2 / 10 K

Installation position

mbar

< 2 at +/- 30° tilted position with model IS-21-S and IS-21-F

CE- conformitiy

„

Pressure equipment directive

97/23/EC

„

EMC directive

2004/108/EC, EN 61 326 Emission (Group 1, Class B) and Immunity

(industrial locations)

„

Directive ATEX of equipment

intended for use in potentially

explosive atmospheres

94/9/EC

Ex-protection

ATEX

Category

8)

1G, 1/2G, 2G, 1D

9)

, 1/2D

9)

, 2D

9)

, M1, M2

Ignition protection type

Ex ia I/II C T4, Ex ia I/II C T5, Ex ia I/II C T6

8)

Read the operating conditions and safety-relevant data in the EC-type

examination certificate in any case (BVS 04 ATEX E 068 X)

9)

Not for IS-20-H

Ex-protection

FM, CSA

Class I, II and III

Ignition protection type

Instrinsic safe Class I, II, III Division 1,
Group A, B, C, D, E, F, G and Class I, Zone 0 AEx ia II C

Approval German Lloyd GL

Environmental Category D, F, EMC 1

RF-immunity

V/m

10

Burst

kV

2

Shock resistance » Model IS-2X-S g

1000

10)

according to IEC 60068-2-27 (mechanical shock)

» Model IS-2X-F g

600

10)

according to IEC 60068-2-27 (mechanical shock)

10)

not with ship approval

Vibration resistance » IS-2X-S g

20

11)

according to IEC 60068-2-6 (vibration under resonance)

» IS-2X-F g

10

11)

according to IEC 60068-2-6 (vibration under resonance)

11)

with ship approval: Category H, up to 2KHz

Wiring protection

„

Reverse polarity protection

U+ towards U-