B. no heat condition – American Dryer Corp. ADG-385 User Manual
Page 45

41
B. No Heat Condition
The following procedure must be performed with
the microprocessor controller (computer) display
in the normal operating mode, and the heat indicator
dot on, and the L.E.D. heat output light on. Voltage
is 24 VAC unless otherwise specified.
1. Check to see if DSI module fault indicator L.E.D.
is on or flashing. If yes, refer to "DSI" Trouble
shooting Booklet. (P/N: 450142)
2. Check for voltage (approx. 25VAC) across DSI
module terminals "STAT" or "TH" and "GND."
If voltage is evident, refer to "DSI" Trouble
Shooting Booklet. (P/N: 450142)
3. Check for voltage between TB#2 and TB#7. If
voltage is evident, problem is break in wire or
termination between TB#2 and TB#7, and the
DSI module "STAT", "TH", or "GND" terminal.
See also other documents in the category American Dryer Corp. Dryers:
- SL2929 (8 pages)
- AD-15 Phase 7 (31 pages)
- ML-75DIII (65 pages)
- AD-236 (33 pages)
- AD-50V (61 pages)
- ML-96HS (38 pages)
- 75 lb (6 pages)
- SL2020 (8 pages)
- AD-758DV (52 pages)
- Aquatex AD-76 (36 pages)
- MDG-75 (66 pages)
- MLG-130DR (HSI) (45 pages)
- MLG31PCB (44 pages)
- AD-410 (72 pages)
- AD-75THS (49 pages)
- Direct Spark Ignition ADG-530DSi II (33 pages)
- MLG32PD3 (39 pages)
- ML-55 (52 pages)
- ML-96 (34 pages)
- ADG-410 (75 pages)
- ADG-320D (53 pages)
- Phase 7 Gas/Steam AD-464 (62 pages)
- AD-120ES (50 pages)
- Gas/Electric/Steam ML-55HS (56 pages)
- AD-840 (47 pages)
- MDG31 (26 pages)
- D20 (37 pages)
- Aquatex AD-52 (37 pages)
- Phase 7 D30 (39 pages)
- 30 lb. Stacked Models (26 pages)
- ADH-120 (46 pages)
- ML-96D (43 pages)
- Super AD-50 (54 pages)
- ML-122 (52 pages)
- SL31 (12 pages)
- Super AD-30 (63 pages)
- MDG30V (52 pages)
- AD-670 (60 pages)
- SL31AD-15 (72 pages)
- ADS-464 II (80 pages)
- ML-190 (42 pages)
- Heat Reclaimer AD-170HR (20 pages)
- 50 lb. Single Pocket MDG50V (52 pages)
- 24 VAC Phase 5 AD-330 (40 pages)
- D75 (42 pages)