L. Motor Contactor (1Ø Motor)

This motor contactor used on single phase dryers, is

located in the rear of the machine, in the Electrical

Panel Box. It's purpose is to transfer the higher

voltage to the motor when the contactor coil voltage

has been achieved. The contactor will have a filter ca-

pacitor across the coil connections. This helps smooth

out the 24 volt signal from the computer board.

M. Non-Reversing Contactor (3Ø Motor)

The non-reversing contactor is used on 3 phase

non-reversing dryers and is located on the upper left hand

side of the dryer (view from rear). It is through the contactor

that the voltage inputs are fed. Its purpose is to transfer the

higher voltage to the motor when the contactor coil voltage

have been achieved. The contactor will have a filter

capacitor across the coil connections. This helps smooth

out the 24 volt signal from the computer board.

N. Hi-Limit Thermostat

The hi-limit thermostat is another safety

device that we use on gas and electric

models. The hi-limit is located in the

burner or oven area. The hi-limit switch

cuts off the heat if the temperature exceeds

330° for gas models. Under normal conditions

the only way this device would shut off the

heat is when the air flow changes to the extent

of making the flame brush up against it.