Maintenance

The lubricant is used to help the O-ring remain in place.

Figure 43: XS group

Figure 44: 3298, SP3298, and V3298 S, M, and L groups

10. For the SP3298, complete these steps:

a) Place the backplate (444) face down on the work surface.
b) Place the containment shell with the reverse thrust bearing in the backplate.
c) Place a clamp ring (141C) over the containment shell and secure with clamp ring bolts

(356A).

d) Coat the O-ring (412V) with an O-ring lubricant. Insert the O-ring in the backplate.

The lubricant helps the O-ring remain in place.

Figure 45: SP3298