Product Description

Nameplate field

Explanation

2

Category 2

G/D

Pump can be used when gas and dust are present

T4

Temperature class

Table 5: Temperature class definitions

Code

Maximum permissible surface

Minimum permissible surface

temperature in °F (°C)

temperature in °F (°C)

T1

842 (450)

700 (372)

T2

572 (300)

530 (277)

T3

392 (200)

350 (177)

T4

275 (135)

235 (113)

T5

212 (100)

Option not available

T6

185 (85)

Option not available

NOTICE:
Make sure that the code classifications on the pump are compatible with the specific
environment in which you plan to install the equipment. If they are not compatible, do not
operate the equipment and contact your ITT representative before you proceed.