Maintenance

.

Figure 28: Magnet assembly

3. Tighten the jacking screws evenly and in sequence until you can remove the magnet

assembly (740B).

4. Remove the magnet assembly (740B) and place it away from any attracting metals.

Figure 29: Magnet assembly removal

5. For the L and M group pumps, remove the 5/16 in. wear ring capscrew (372Y) and the wear

ring from the bottom of the bearing frame (228).

Figure 30: L and M group wear ring removal