1 INTRODUCTION
RHT-Air comes with a high precision and stability sensor to measure both
temperature and relative humidity. Because it operates with a
microprocessor, it can be fully configured through its USB and IEEE 802.15.4
interfaces, using Modbus RTU commands. The software DigiConfig enables
for all the equipment’s resources to be configured.
RHT-Air can be configured to display the temperature and Relative Humidity
measured or even, the temperature and the Dew Point
RHT-Air should be connected (via wireless) to an AirGate-Modbus so that
its registers can be read whenever it is in operation.
1.1 IDENTIFICATION
The following elements appear in the front part of the equipment:
Fig. 1 – RHT-Air main screen
Communication Indicator (COM): It signals that the device is receiving data
from the Modbus network.
Button (Programming): This button is used to configure the Modbus
address, the Update Interval and screen changes.
Temperature: Room temperature measured by the equipment.
Relative Humidity: Relative Humidity measurement.
Fig. 2 – RHT-Air’s second screen
Communication Address: Programmed value to identify the Modbus
network equipment. Programmable between 1 and 246.
2 SPECIFICATIONS
Equipment’s operating
temperature
RTH-Air = from -10 °C to 70 °C
Electromagnetic
compatibility
EMC: EN61326-1:2006 CISPR11/EN55011,
EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-6, EN61000-4-8
Sensor’s measurement
range
Temperature: -40.0 °C to 100.0 °C.
Relative Humidity (RH): 0.0 to 100.0 % RH.
(No Condensation)
Dew point: -40.0 °C and 100.0 °C
Precision of
measurements
See Fig. 3.
Note: measurement errors can be discarded
through the software’s OFFSET parameter.
Resolution of
measurements:
Temperature: 0.1 °C. 14 bits (16383 levels)
Relative Humidity (RH): 0.1 %. 12 bits (4095
levels)
Response time
(Sensor)
Temperature: Up to 30 s in slow moving air.
Humidity: Up to 8 s in softly moving air (20 to
80 % RH).
Interval between updates A minimum of 15 seconds. No more than 30
minutes (1800 s)
Power supply
12 Vdc to 30 Vdc, consumption < 100 mA or
Lithium battery of 3.6 Vcc (1/2 AA), internal.
Connections
• Internal USB Device (Mini-B) for
configuration and firmware update.
• Groove RP SMA (Plug) connector for
antenna.
• Power supply connector.
Wireless
• Maximum transmission power of 25,11
mW (14 dBm).
• Maximum Range: 500 meters line-of-sight
in open field.
• Receptor sensibility - 92 dBm.
• Operation band ISM 2.4 GHz.
• DSSS Technology - Direct Sequence
Spread Spectrum.
• OQPSK Modulation - Offset Quadrature
Phase Shift Keying.
• 15 operation channels.
• AES-CBC-128 (Advanced Encryption
Standard).
Storage
Polycarbonate
Level of protection
The product is suitable for applications that
require a level of protection of up to IP65.
Electronic module box: IP65; Sensor capsule:
IP40.
Dimensions
60 x 70 x 35 mm + antenna 105 mm + sensor
37.2 mm
Weight
171 grams / 40 grams (cable)
DigiConfig software
configuration environment
Configuration Software Windows®.
Menus in Portuguese, English or Spanish.
It configures, reads and displays data on the
screen.
Certifications
CE, ANATEL (0172-13-7089)