beautypg.com

NOVUS TagTemp-USB User Manual

Tagtemp-usb, 1 introduction, 2 technical data

background image

NOVUS AUTOMATION

1/5

TagTemp-USB

TEMPERATURE LOGGER – INSTRUCTIONS V 1.0x A

1 INTRODUCTION

TagTemp-USB is a small portable electronic temperature logger. Its

internal sensor measures local environment temperature and logs

such values in an electronic memory. Logged data, or

ACQUISITIONS, can be later viewed and analyzed on a PC where

they can be opened in tabular and graph forms.
The LogChart II software enables to set up the equipment operation

mode. It is also used for viewing acquisitions. Other parameters such

as end of measurements, logging interval, etc., are easily defined

through the LogChart II software.
Acquisitions can also be exported to be analyzed in other

applications, such as spreadsheet programs.

1.1 IDENTIFICATION
The identification label is on the equipment body. Check if the

features described are in accordance with your order.

Fig. 01 – Front view of the device

Status indicator: This visual indicator reports the status of operation

of equipment through the number of flashes that occur in an interval

of five seconds. The states of operation are:
One flash: The device is waiting to start the log in memory

(standby) or completed a series of logs in memory;

Two flashes: the device is performing logs in memory;
Three flashes: the device is or has gone through an alarm

condition and is not performing logs in memory;

Four flashes: the device is or has gone through an alarm

condition and is performing logs in memory.

2 TECHNICAL DATA

Measure Range

Temperature: –20.0 °C to 70.0 °C.

Accuracy

±

0.1 °C @ 25 ºC.

±

1 °C max. along the entire measured range.

Note: A measure error can be fixed using the

OFFSET parameter in the LogChart II software.

Measurement

Resolutions

Temperature: 0.1 °C.

Memory capacity

32.000 (32 k) logs.

Measurement Interval

5 seconds min.
18 hours max.

Supply

3.0 V lithium battery (CR2032), built-in

Estimated autonomy

• More than 400 days – Sampling rate of 1

minute.

• More than 500 days – Sampling rate of 30

minutes.

Operating temperature

From -20 °C to 70 °C

Case

PC-ABS

Protection

Product suitable for applications requiring up to

IP67 degree of protection. See item "Special

Care".

Dimensions

55 x 37,5 x 15 mm

Equipment -PC data

transfer time

Proportional to the number of records. 20

seconds to 32,000 records.

PC Interface

Micro-USB cable

LogChart ll software

operation environment

Configurator software for Windows ® 8, 7 and

XP.

Menus in Portuguese, English or Spanish.

Sets up, reads and displays data on the

screen.

3 OPERATION

It is only possible to operate the equipment after the LogChart II

software is installed to a PC, according to the steps described in

LogChart II Software section of this manual. The communication

between equipment and PC is performed with the aid of the micro-

USB cable.
The equipment operation mode set up is defined in advance by using

the LogChart II software. Each setting must be defined and the

consequences observed.
The equipment starts and stops logging as defined in settings.