beautypg.com

4 stop / pause / resume buttons, 5 offloading and data visualization, 1 offloading data – NOVUS TagTemp-USB User Manual

Page 3: 2 visualizing data, 1 chart window

background image

TagTemp-USB

NOVUS AUTOMATION

3/5

Average: The registered value will be the average of ten

measurements made on logging interval. The minimum

time between each record is 50 seconds.

Maximum: The value logged will be the maximum value

found within ten consecutive measurements taken within

a predefined interval. The minimum interval between

measurements is 50 seconds.

Minimum: The value logged will be the minimum value

found within ten consecutive measurements taken within

a predefined interval. The minimum interval between

measurements is 50 seconds.

Offset: Makes possible to correct the value logged.
Alarm: Defines limit values that, when exceeded, characterize

an alarm condition. Alarm events are informed to the user

through a flashing mode of the Alarm Indicator.

After filling all the fields select “OK” and settings will be sent to the

equipment.

4.4 STOP / PAUSE / RESUME BUTTONS
These buttons will be enabled once the device is fully configured.
The Stop button allows stop records permanently, so that the device

will only register again after a new configuration by the user.

The Pause / Resume button action sends the appropriate command,

depending on the current registration status:
If the records are In Progress and pressing this button, it will be

send a command to Pause the records.

Pause: pauses the registry allowing it to be resumed later using the

Resume button.

If registration is Paused and pressing this button, it will be send a

command to Resume the records.

Resume: Resumes the records that were interrupted by the Pause

command, without erasing the previous registers of the device

memory, using the same parameter settings previously configured.

5 OFFLOADING AND DATA VISUALIZATION

Data collected are send from equipment to PC. Data can be collected

any time, at the end of the acquisition process or while they are being

acquired. If data collection takes place during the acquisition

process, the process will not be interrupted, following the equipment

configuration.
It is important to "wake up" the equipment before starting

communication.

5.1 OFFLOADING DATA
Data offload is accomplished by clicking the button Offload Data:

During data transference, a status bar indicates remaining data to be

transferred. Data offloading time is proportional to the number of

readings logged.

5.2 VISUALIZING DATA
At the end of values transfer, data can be displayed in a graphical

form.
5.2.1 Chart Window
It is possible to select a region of the chart to zoom in. Zoom

commands can be accessed through the View menu or through

zoom icons from the task bar.
It is also possible to select an area from the chart to zoom in by

clicking and dragging the mouse, thus creating a zoom region

starting from the upper left corner on the chart area.
The graphic curves can be vertically dragged with a right-click and

dragging the mouse up and down.

Fig. 06 - Chart window