American Electric Lighting CVM User Manual
Installation instructions corvus medium (cvm), Warning, Warning caution

INSTALLATION INSTRUCTIONS
CORVUS MEDIUM (CVM)
American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH
DRAWING NO. A68045 REV C
(FRONT)
©2008 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-68045
OPENING & CLOSING THE UNIT:
OPENING & CLOSING THE UNIT:
1. OPEN THE UNIT. (SEE “OPENING AND CLOSING THE UNIT”
1. OPEN THE UNIT. (SEE “OPENING AND CLOSING THE UNIT”
ABOVE.)
ABOVE.)
2. UNSCREW THE FOUR SCREWS ATTACHING THE POWER PAD
2. UNSCREW THE FOUR SCREWS ATTACHING THE POWER PAD
TO THE UNIT, TOTALLY DISENGAGING THEM FROM THE
TO THE UNIT, TOTALLY DISENGAGING THEM FROM THE
CASTING.
CASTING.
3. REMOVE THE SOCKET HOLDER (SEE LAMP INSTALLATION
3. REMOVE THE SOCKET HOLDER (SEE LAMP INSTALLATION
INSTRUCTIONS) GRIPPING THE BRACKET, REMOVE THE
INSTRUCTIONS) GRIPPING THE BRACKET, REMOVE THE
POWER PAD FROM THE UNIT, DISCONNECTING THE WIRING
POWER PAD FROM THE UNIT, DISCONNECTING THE WIRING
BY USE OF THE QUICK DISCONNECT.
BY USE OF THE QUICK DISCONNECT.
4. TO REINSTALL THE POWER PAD REPEAT THE STEPS ABOVE
4. TO REINSTALL THE POWER PAD REPEAT THE STEPS ABOVE
IN REVERSE ORDER.
IN REVERSE ORDER.
NOTE: CHECK TO INSURE THAT THE WIRES ARE NOT PINCHED
NOTE: CHECK TO INSURE THAT THE WIRES ARE NOT PINCHED
AGAINST THE CASTING DURING RE-INSTALLATION OF THE
AGAINST THE CASTING DURING RE-INSTALLATION OF THE
POWER PAD.
POWER PAD.
POWERPAD REMOVAL & INSTALLATION:
POWERPAD REMOVAL & INSTALLATION:
11.. TO OPEN THE FIXTURE, LOCATE THE LATCH AT THE FRONT
TO OPEN THE FIXTURE, LOCATE THE LATCH AT THE FRONT
AND FLIP IT TOWARDS THE FRONT. (SEE FIGURE 1.)
AND FLIP IT TOWARDS THE FRONT. (SEE FIGURE 1.)
2.
2. OPEN THE HOOD.
OPEN THE HOOD.
3. SECURE THE HOOD ON ITS OPEN POSITION USING THE ROD.
3. SECURE THE HOOD ON ITS OPEN POSITION USING THE ROD.
(SEE FIGURE 2.)
(SEE FIGURE 2.)
4. TO CLOSE THE FIXTURE, SIMPLY
4. TO CLOSE THE FIXTURE, SIMPLY UN-SECURE THE ROD AND
UN-SECURE THE ROD AND
CLOSE THE
CLOSE THE HOOD AND RE-POSITION THE LATCH ON ITS PLACE
HOOD AND RE-POSITION THE LATCH ON ITS PLACE
PUSHING IT TOWARDS THE BACK UNTIL IT ENGAGES.
PUSHING IT TOWARDS THE BACK UNTIL IT ENGAGES.
(SEE FIGURE 3.)
(SEE FIGURE 3.)
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
WARNING
!
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION,
CONSULT LOCAL CODE AUTHORITY
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
WARNING
CAUTION
!
!
FIGURE 1
FIGURE 1
CLOSED HOOD - STREET SIDE VIEW
CLOSED HOOD - STREET SIDE VIEW
FIGURE 2
FIGURE 2
OPEN HOOD - TOP VIEW
OPEN HOOD - TOP VIEW
LATCH
LATCH
ROD
ROD
ROD
ROD
FIGURE 3