INSTALLATION INSTRUCTIONS
SERIES NEMA LED 2
American Electric Lighting a division of Acuity Lighting Group, Inc.
DRAWING NO. A72996 REV A (FRONT)
©2014 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-70-72996
1. FEED THE WIRES THROUGH THE RUBBER BIRD
SHIELD INSIDE THE HOUSING, DRESS THE WIRES
SO THEY DO NOT INTERFERENCE WITH ANY
COMPONENTS.
2. TIGHTEN THE FITTER BOLTS SECURELY.
3. LEVEL THE FIXTURE USING THE LEVELING SCREW.
WIRING THE FIXTURE
WIRING THE FIXTURE
4. REMOVE OPTICAL ASSEMBLY FROM THE HOUSING.
DETACH THE TWO SPRING LATCHES OF THE
OPTICAL ASSEMBLY. PULL LATCH UP. OPTICAL
ASSEMBLY WILL BE SUPPORTED BY A TETHER THAT
IS ATTACHED TO THE HOUSING.
5. CONNECT THE WIRES TO THE PROPER TERMINALS ON
THE TERMINAL BLOCK. REFER TO THE WIRING
DIAGRAM FOR CONNECTION INFORMATION.
RECOMMENDED TORQUE FOR TERMINAL BLOCK
SCREWS 35 IN-LBS.
INSTALLING THE OPTICAL ASSEMBLY
INSTALLING THE OPTICAL ASSEMBLY
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
WARNING
!
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION,
CONSULT LOCAL CODE AUTHORITY BEFORE INSTALLING VERIFY THAT THE SUPPLY VOLTAGE
MATCHES THAT REQUIRED BY THE FIXTURE AS SPECIFIED ON THE DATA LABEL.
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
WARNING
CAUTION
!
!
6. ROUTE THE WIRES AND TETHER INSIDE THE HEAT SINK
AND HOUSING COMPARTMENT WHILE THE OPTICAL
ASSEMBLY IS ALIGNED TO THE HOUSING. ATTACH
SPRING LATCHES OF OPTIC ASSEMBLY TO THE TABS
ON THE SIDE OF THE HOUSING AND PULL LATCH
HANDLE DOWN TO LOCK IN PLACE.
MOUNTING THE FIXTURE
MOUNTING THE FIXTURE
LEVELING SCREW
BIRD SHIELD
FITTER BOLTS
OPTICAL
ASSEMBLY
TETHER
ELECTRICAL
CONNECTION