American Electric Lighting UnderPass-581 User Manual
Maintenance, Installation, Warning
INSTALLATION & MAINTENANCE INSTRUCTIONS
SIDELITE LUMINAIRE
American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA
DRAWING NO. B07796 REV E
©2003 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-07796
WARNING
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
REAR HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
SCREW (A)
FRONT HOUSING (B)
REFRACTOR
REAR HOUSING (D)
SCREW (E)
Clean reflector with mild soap or household type detergent.
Do not use acid or caustic cleaners.
1. Disconnect power to fixture.
2. Loosen screws (A) until free.
3. Open front housing & let hang on tethers.
4. Replace lamp and close front housing.
3. Install reflector, lamp and front housing.
Pull wires back through fixture & make connections in rear
housing compartment.
Loosen screws (E). Remove cover plate. Make wiring
connections. Replace plate.
1. Mount to 3 1/4" or 4" outlet box marked for wet location
using holes provided around outlet hole in rear housing.
1. Knock out 3 slugs in rear housing (D).
2. Mount with 3 bolts.
1. Loosen screws (A) until free.
2. Open front housing (B).
3. Remove screws holding tethers in rear housing.
4. Remove front housing.
5. Remove reflector by loosening its' two screws.
CLEANING
RELAMPING
MAINTENANCE
2. SIDE CONDUIT HOLES (OPTIONAL)
1. OUTLET HOLE
WIRING
OUTLET BOX MOUNTING
MOUNTING WITH 3 BOLTS
INSTALLATION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL
AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
WARNING
CAUTION
!
!
!