beautypg.com

Yoke mount tenon mount, Wiring, Bezel replacement – American Electric Lighting ACP User Manual

Page 2: Lamp servicing

background image

American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH

DRAWING NO. A71218 REV B

(REAR)

©2007 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-70-71218

WIRING

WIRING

YOKE MOUNT:

YOKE MOUNT:

OPTIONAL FACTORY PRE-WIRED

OPTIONAL FACTORY PRE-WIRED

FLOODS ARE FURNISHED WITH 3 FEET OF FLEXIBLE

FLOODS ARE FURNISHED WITH 3 FEET OF FLEXIBLE

CABLE READY FOR CONNECTION TO SUPPLY. FOR

CABLE READY FOR CONNECTION TO SUPPLY. FOR

STANDARD UNITS THAT ARE NOT PRE-WIRED, OPEN

STANDARD UNITS THAT ARE NOT PRE-WIRED, OPEN

BEZEL BY LOOSENING THE 2 CLOSURE SCREWS OR

BEZEL BY LOOSENING THE 2 CLOSURE SCREWS OR

LATCHES LOCATED AT THE TOP OF FLOOD. LIFT THE

LATCHES LOCATED AT THE TOP OF FLOOD. LIFT THE

SHIELD TO EXPOSE THE WIRING COMPARTMENT.

SHIELD TO EXPOSE THE WIRING COMPARTMENT.

REMOVE THE COMPRESSION FITTING AND GROMMET,

REMOVE THE COMPRESSION FITTING AND GROMMET,

FEED CABLE THROUGH THE WIRE ENTRY HOLE. SLIP

FEED CABLE THROUGH THE WIRE ENTRY HOLE. SLIP

THE GROMMET AND COMPRESSION FITTING OVER

THE GROMMET AND COMPRESSION FITTING OVER

THE CABLE AND REASSEMBLE TO HOUSING. USING

THE CABLE AND REASSEMBLE TO HOUSING. USING

THE WIRING DIAGRAM AS A GUIDE, MAKE CONNECTIONS

THE WIRING DIAGRAM AS A GUIDE, MAKE CONNECTIONS

TO THE TERMINAL BLOCK. ATTACH THE GREEN GROUND

TO THE TERMINAL BLOCK. ATTACH THE GREEN GROUND

WIRE TO THE GROUNDING BOSS WITH THE GREEN

WIRE TO THE GROUNDING BOSS WITH THE GREEN

GROUND SCREW PROVIDED. MULTI-VOLT BALLAST ARE

GROUND SCREW PROVIDED. MULTI-VOLT BALLAST ARE

FACTORY WIRED FOR 120V OPERATION UNLESS

FACTORY WIRED FOR 120V OPERATION UNLESS

OTHERWISE SPECIFIED. CABLE SHOULD BE #16 AWG

OTHERWISE SPECIFIED. CABLE SHOULD BE #16 AWG

MINIMUM, TYPE SJ, SO, OR SJT-WA, SUITABLE FOR

MINIMUM, TYPE SJ, SO, OR SJT-WA, SUITABLE FOR

105C OPERATION

105C OPERATION

TENON MOUNT:

TENON MOUNT:

OPEN ACCESS DOOR ON TENON

OPEN ACCESS DOOR ON TENON

MOUNT, FEED SUPPLY WIRES THROUGH BOTTOM OF

MOUNT, FEED SUPPLY WIRES THROUGH BOTTOM OF

TENON MOUNT AND OUT ACCESS DOOR. SLIP TENON

TENON MOUNT AND OUT ACCESS DOOR. SLIP TENON

MOUNT OVER POLE TENON AND CONNECT SUPPLY

MOUNT OVER POLE TENON AND CONNECT SUPPLY

LEADS TO FIXTURE WIRES. PUSH LEADS BACK INTO

LEADS TO FIXTURE WIRES. PUSH LEADS BACK INTO

WIRING COMPARTMENT OF TENON MOUNT AND

WIRING COMPARTMENT OF TENON MOUNT AND

REPLACE COVER.

REPLACE COVER.

BEZEL REPLACEMENT

BEZEL REPLACEMENT

OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR

OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR

LATCHES. LOOSEN THE HINGE KEEPER SCREW AND SLIDE

LATCHES. LOOSEN THE HINGE KEEPER SCREW AND SLIDE

THE BEZEL OFF. ASSEMBLE THE REPLACEMENT BEZEL IN

THE BEZEL OFF. ASSEMBLE THE REPLACEMENT BEZEL IN

THE REVERSE MANNER.

THE REVERSE MANNER.

LAMP SERVICING

LAMP SERVICING

OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR

OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR

LATCHES. ALLOW IT TO HANG FREELY ON IT’S HINGE.

LATCHES. ALLOW IT TO HANG FREELY ON IT’S HINGE.

THE LAMP SHOULD THEN BE UNSCREWED COUNTER

THE LAMP SHOULD THEN BE UNSCREWED COUNTER

CLOCKWISE UNTIL FREE. THE LAMP CAN THEN BE

CLOCKWISE UNTIL FREE. THE LAMP CAN THEN BE

REPLACED BY REVERSING THE PROCEDURE.

REPLACED BY REVERSING THE PROCEDURE.

ENSURE WHEN RELAMPING TO USE THE CORRECT

ENSURE WHEN RELAMPING TO USE THE CORRECT

LAMP TYPE AND VALUE.

LAMP TYPE AND VALUE.

RELAMP IN ACCORDANCE WITH THE BALLAST

RELAMP IN ACCORDANCE WITH THE BALLAST

EMPLOYED FOR A MAXIMUM OF 400W HPS OR 400W MH.

EMPLOYED FOR A MAXIMUM OF 400W HPS OR 400W MH.

SET

SET

SCREWS (4)

SCREWS (4)

HINGE

HINGE

SCREW

SCREW

ACCESS

ACCESS

DOOR

DOOR

YOKE MOUNT

TENON MOUNT

IF LAMP IS MARKED

IF LAMP IS MARKED

IT CONTAINS MERCURY.

IT CONTAINS MERCURY.

FOLLOW DISPOSAL LAWS.

FOLLOW DISPOSAL LAWS.

SEE WWW.LAMPRECYCLE.ORG

SEE WWW.LAMPRECYCLE.ORG

Hg