Yoke mount tenon mount, Wiring, Bezel replacement – American Electric Lighting ACP User Manual
Page 2: Lamp servicing
American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH
DRAWING NO. A71218 REV B
(REAR)
©2007 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-70-71218
WIRING
WIRING
YOKE MOUNT:
YOKE MOUNT:
OPTIONAL FACTORY PRE-WIRED
OPTIONAL FACTORY PRE-WIRED
FLOODS ARE FURNISHED WITH 3 FEET OF FLEXIBLE
FLOODS ARE FURNISHED WITH 3 FEET OF FLEXIBLE
CABLE READY FOR CONNECTION TO SUPPLY. FOR
CABLE READY FOR CONNECTION TO SUPPLY. FOR
STANDARD UNITS THAT ARE NOT PRE-WIRED, OPEN
STANDARD UNITS THAT ARE NOT PRE-WIRED, OPEN
BEZEL BY LOOSENING THE 2 CLOSURE SCREWS OR
BEZEL BY LOOSENING THE 2 CLOSURE SCREWS OR
LATCHES LOCATED AT THE TOP OF FLOOD. LIFT THE
LATCHES LOCATED AT THE TOP OF FLOOD. LIFT THE
SHIELD TO EXPOSE THE WIRING COMPARTMENT.
SHIELD TO EXPOSE THE WIRING COMPARTMENT.
REMOVE THE COMPRESSION FITTING AND GROMMET,
REMOVE THE COMPRESSION FITTING AND GROMMET,
FEED CABLE THROUGH THE WIRE ENTRY HOLE. SLIP
FEED CABLE THROUGH THE WIRE ENTRY HOLE. SLIP
THE GROMMET AND COMPRESSION FITTING OVER
THE GROMMET AND COMPRESSION FITTING OVER
THE CABLE AND REASSEMBLE TO HOUSING. USING
THE CABLE AND REASSEMBLE TO HOUSING. USING
THE WIRING DIAGRAM AS A GUIDE, MAKE CONNECTIONS
THE WIRING DIAGRAM AS A GUIDE, MAKE CONNECTIONS
TO THE TERMINAL BLOCK. ATTACH THE GREEN GROUND
TO THE TERMINAL BLOCK. ATTACH THE GREEN GROUND
WIRE TO THE GROUNDING BOSS WITH THE GREEN
WIRE TO THE GROUNDING BOSS WITH THE GREEN
GROUND SCREW PROVIDED. MULTI-VOLT BALLAST ARE
GROUND SCREW PROVIDED. MULTI-VOLT BALLAST ARE
FACTORY WIRED FOR 120V OPERATION UNLESS
FACTORY WIRED FOR 120V OPERATION UNLESS
OTHERWISE SPECIFIED. CABLE SHOULD BE #16 AWG
OTHERWISE SPECIFIED. CABLE SHOULD BE #16 AWG
MINIMUM, TYPE SJ, SO, OR SJT-WA, SUITABLE FOR
MINIMUM, TYPE SJ, SO, OR SJT-WA, SUITABLE FOR
105C OPERATION
105C OPERATION
TENON MOUNT:
TENON MOUNT:
OPEN ACCESS DOOR ON TENON
OPEN ACCESS DOOR ON TENON
MOUNT, FEED SUPPLY WIRES THROUGH BOTTOM OF
MOUNT, FEED SUPPLY WIRES THROUGH BOTTOM OF
TENON MOUNT AND OUT ACCESS DOOR. SLIP TENON
TENON MOUNT AND OUT ACCESS DOOR. SLIP TENON
MOUNT OVER POLE TENON AND CONNECT SUPPLY
MOUNT OVER POLE TENON AND CONNECT SUPPLY
LEADS TO FIXTURE WIRES. PUSH LEADS BACK INTO
LEADS TO FIXTURE WIRES. PUSH LEADS BACK INTO
WIRING COMPARTMENT OF TENON MOUNT AND
WIRING COMPARTMENT OF TENON MOUNT AND
REPLACE COVER.
REPLACE COVER.
BEZEL REPLACEMENT
BEZEL REPLACEMENT
OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR
OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR
LATCHES. LOOSEN THE HINGE KEEPER SCREW AND SLIDE
LATCHES. LOOSEN THE HINGE KEEPER SCREW AND SLIDE
THE BEZEL OFF. ASSEMBLE THE REPLACEMENT BEZEL IN
THE BEZEL OFF. ASSEMBLE THE REPLACEMENT BEZEL IN
THE REVERSE MANNER.
THE REVERSE MANNER.
LAMP SERVICING
LAMP SERVICING
OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR
OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR
LATCHES. ALLOW IT TO HANG FREELY ON IT’S HINGE.
LATCHES. ALLOW IT TO HANG FREELY ON IT’S HINGE.
THE LAMP SHOULD THEN BE UNSCREWED COUNTER
THE LAMP SHOULD THEN BE UNSCREWED COUNTER
CLOCKWISE UNTIL FREE. THE LAMP CAN THEN BE
CLOCKWISE UNTIL FREE. THE LAMP CAN THEN BE
REPLACED BY REVERSING THE PROCEDURE.
REPLACED BY REVERSING THE PROCEDURE.
ENSURE WHEN RELAMPING TO USE THE CORRECT
ENSURE WHEN RELAMPING TO USE THE CORRECT
LAMP TYPE AND VALUE.
LAMP TYPE AND VALUE.
RELAMP IN ACCORDANCE WITH THE BALLAST
RELAMP IN ACCORDANCE WITH THE BALLAST
EMPLOYED FOR A MAXIMUM OF 400W HPS OR 400W MH.
EMPLOYED FOR A MAXIMUM OF 400W HPS OR 400W MH.
SET
SET
SCREWS (4)
SCREWS (4)
HINGE
HINGE
SCREW
SCREW
ACCESS
ACCESS
DOOR
DOOR
YOKE MOUNT
TENON MOUNT
IF LAMP IS MARKED
IF LAMP IS MARKED
IT CONTAINS MERCURY.
IT CONTAINS MERCURY.
FOLLOW DISPOSAL LAWS.
FOLLOW DISPOSAL LAWS.
SEE WWW.LAMPRECYCLE.ORG
SEE WWW.LAMPRECYCLE.ORG
Hg