A72934_sht2, Installation instructions, Caution – American Electric Lighting ARDL User Manual
Page 2
American Electric Lighting a division of Acuity Lighting Group, Inc.
DRAWING NO. A72934 REV --
(BACK)
©2014 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-70-72934
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
AMERICAN REVOLUTION DELUXE LED cont.
AMERICAN REVOLUTION DELUXE LED cont.
MOUNTING:
MOUNTING:
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
2. ORIENT THE UNIT SO THE CLOSURE SCREWS (OR
2. ORIENT THE UNIT SO THE CLOSURE SCREWS (OR
TRIGGER LATCHES IF EQUIPPED) ARE TO THE
TRIGGER LATCHES IF EQUIPPED) ARE TO THE
STREET SIDE.
STREET SIDE.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
VERY AUDIBLE SNAP.
VERY AUDIBLE SNAP.
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING
AND TURNING SIMULTANEOUSLY UNTIL THE CUPOLA
AND TURNING SIMULTANEOUSLY UNTIL THE CUPOLA
WINDOW IS FACING NORTH. THE CUPOLA BASE AND
WINDOW IS FACING NORTH. THE CUPOLA BASE AND
THE PHOTOCONTROL RECEPTACLE ARE KEYED SO THE
THE PHOTOCONTROL RECEPTACLE ARE KEYED SO THE
PHOTOCONTROL TURNS AS THE CUPOLA DOES.
PHOTOCONTROL TURNS AS THE CUPOLA DOES.
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
STOPS AND REFUSES TO TURN.
STOPS AND REFUSES TO TURN.
L ADDER REST INSTALLATION:
ADDER REST INSTALLATION:
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE
FORCE. HOWEVER, IT CAN BE REATTACHED WITH A
FORCE. HOWEVER, IT CAN BE REATTACHED WITH A
1/4-20X3/4 BOLT AND NUT AVAILABLE IN THE LADDER REST
1/4-20X3/4 BOLT AND NUT AVAILABLE IN THE LADDER REST
REPLACEMENT KIT (THE KIT ALSO CONTAINS TWO
REPLACEMENT KIT (THE KIT ALSO CONTAINS TWO
ADDITIONAL LADDER RESTS.) NOTE: THE LADDER REST IS
ADDITIONAL LADDER RESTS.) NOTE: THE LADDER REST IS
A PRESS FIT DESIGN INTENDED FOR INSTALLATION
A PRESS FIT DESIGN INTENDED FOR INSTALLATION
AFTER THE UNIT IS INSTALLED ONTO THE POST TOP.
AFTER THE UNIT IS INSTALLED ONTO THE POST TOP.
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE
FIGURE 3) INTO THE LADDER REST HOLE LOCATED ON
FIGURE 3) INTO THE LADDER REST HOLE LOCATED ON
THE LEFT AND RIGHT SIDE OF THE LOWER HOUSING
THE LEFT AND RIGHT SIDE OF THE LOWER HOUSING
JUST ABOVE THE MOUNT SET SCREWS.
JUST ABOVE THE MOUNT SET SCREWS.
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK
THE LADDER REST INTO THE HOLE. BE SURE TO KEEP
THE LADDER REST INTO THE HOLE. BE SURE TO KEEP
THE LADDER REST LINED UP WITH THE HOLE SO THAT
THE LADDER REST LINED UP WITH THE HOLE SO THAT
THERE SI NO DAMAGE TO THE PIN.
THERE SI NO DAMAGE TO THE PIN.
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
AND NUT.
AND NUT.
CAUTION
DO NOT TIGHTEN SET SCREWS
BEYOND 15 ft-lb. TORQUE.
!
CAUTION
THE LADDER REST IS FOR
COSMETIC PURPOSES ONLY. IT
IS NOT INTENDED FOR USE AS
AN ACTUAL REST FOR A LADDER.
!
PHOTOCONTROL:
PHOTOCONTROL:
NOTE: NO TOOLING IS NECESSARY FOR THE
NOTE: NO TOOLING IS NECESSARY FOR THE
PHOTOCONTROL INSTALLATION OR ADJUSTMENT.
PHOTOCONTROL INSTALLATION OR ADJUSTMENT.
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED TO
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED TO
BE INSTALLED. SEE FOLLWING STEPS.
BE INSTALLED. SEE FOLLWING STEPS.
- IF “NR” WAS SPECIFIED, THE STEPS BELOW ARE
- IF “NR” WAS SPECIFIED, THE STEPS BELOW ARE
NOT NECESSARY.
NOT NECESSARY.
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF
IT AND LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS
IT AND LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS
VERY RIGID AND TIGHT, DESIGNED SO IT DOESN’T
VERY RIGID AND TIGHT, DESIGNED SO IT DOESN’T
EASILY COME OFF. HOWEVER, IT MAY BE REMOVED
EASILY COME OFF. HOWEVER, IT MAY BE REMOVED
BY HAND.
BY HAND.
FIGURE 3
FIGURE 3
LADDER REST INSTALLATION
LADDER REST INSTALLATION
PIN
PIN
GENTLY KNOCK HERE
GENTLY KNOCK HERE
FOR INSTALLATION.
FOR INSTALLATION.
NOTE:
NOTE:
THIS DEVICE COMPLIES WITH PART 18 THE FCC RULES BUT MAY
THIS DEVICE COMPLIES WITH PART 18 THE FCC RULES BUT MAY
CAUSE INTERFERENCE WITH CORDLESS AND CELL PHONES,
CAUSE INTERFERENCE WITH CORDLESS AND CELL PHONES,
RADIOS, TELEVISIONS AND OTHER ELECTRONIC DEVICES.
RADIOS, TELEVISIONS AND OTHER ELECTRONIC DEVICES.
TO CORRECT THE PROBLEM MOVE THE DEVICE AWAY FROM THE
TO CORRECT THE PROBLEM MOVE THE DEVICE AWAY FROM THE
LUMINARY OR PLUG INTO A DIFFERENT OUTLET.
LUMINARY OR PLUG INTO A DIFFERENT OUTLET.
THIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT
THIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT
AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY
AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY
COMMUNICATIONS EQUIPMENT OR OTHER CRITICAL NAVIGATION
COMMUNICATIONS EQUIPMENT OR OTHER CRITICAL NAVIGATION
OR COMMUNICATION EQUIPMENT OPERATING BETWEEN
OR COMMUNICATION EQUIPMENT OPERATING BETWEEN
0.45-30 MHz.
0.45-30 MHz.
PHOTOCONTROL CONT:
PHOTOCONTROL CONT:
1. INSERT THE ROAM NODE INTO THE RECEPTACLE. (ROAM
1. INSERT THE ROAM NODE INTO THE RECEPTACLE. (ROAM
NODE ORDERED SEPARATELY).
NODE ORDERED SEPARATELY).
2. INSERT THE CUPOLA WINDOW (SEE FIGURE 4) (CUPOLA
2. INSERT THE CUPOLA WINDOW (SEE FIGURE 4) (CUPOLA
WINDOW CAME INSIDE THE FIXTURE).
WINDOW CAME INSIDE THE FIXTURE).
3. ATTACH THE CUPOLA CAP (SEE FIGURE 4). IT SHOULD
3. ATTACH THE CUPOLA CAP (SEE FIGURE 4). IT SHOULD
ATTACH WITH A VERY AUDIBLE SNAP. (CUPOLA CAP CAME
ATTACH WITH A VERY AUDIBLE SNAP. (CUPOLA CAP CAME
INSIDE THE FIXTURE).
INSIDE THE FIXTURE).
4. TURN THE ROAM NODE WINDOW TOWARD NORTH BY
4. TURN THE ROAM NODE WINDOW TOWARD NORTH BY
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING
AND TURNING SIMULTANEOUSLY UNTIL THE CUPOLA
AND TURNING SIMULTANEOUSLY UNTIL THE CUPOLA
WINDOW IS FACING NORTH. THE CUPOLA BASE AND
WINDOW IS FACING NORTH. THE CUPOLA BASE AND
THE PHOTOCONTROL RECEPTACLE ARE KEYED SO THE
THE PHOTOCONTROL RECEPTACLE ARE KEYED SO THE
ROAM NODE TURNS AS THE CUPOLA DOES.
ROAM NODE TURNS AS THE CUPOLA DOES.
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
STOPS AND REFUSES TO TURN.
STOPS AND REFUSES TO TURN.
ROAM CONCIERGE/VIEW (DE OR VE OPTIONS):
ROAM CONCIERGE/VIEW (DE OR VE OPTIONS):
FIGURE 4
FIGURE 4
CUPOLA WINDOW AND CAP INSTALLATION
CUPOLA WINDOW AND CAP INSTALLATION
CUPOLA CAP
CUPOLA CAP
CUPOLA WINDOW
CUPOLA WINDOW
CUPOLA
CUPOLA