background image

American Electric Lighting a division of Acuity Lighting Group, Inc. Granville, OH

DRAWING NO. A68128 REV --

(BACK)

©2009 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-71-68128

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

VALIANT SERIES POST TOP LED VERSION cont.

VALIANT SERIES POST TOP LED VERSION cont.

MOUNTING:

MOUNTING:

NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN

NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN

EXTERIOR DIAMETER BETWEEN 2.375” AND 3“

EXTERIOR DIAMETER BETWEEN 2.375” AND 3“

1. PRIOR TO PLACING THE UNIT ONTO THE POLE REMOVE

1. PRIOR TO PLACING THE UNIT ONTO THE POLE REMOVE

THE BASE COVER FROM THE UNIT. (SEE “OPENING &

THE BASE COVER FROM THE UNIT. (SEE “OPENING &

CLOSING THE UNIT” AND “BASE COVER REMOVAL &

CLOSING THE UNIT” AND “BASE COVER REMOVAL &

INSTALLATION” SECTION.)

INSTALLATION” SECTION.)

NOTE: IF THE UNIT IS PRE-WIRED, REMOVAL OF THE

NOTE: IF THE UNIT IS PRE-WIRED, REMOVAL OF THE

BASE COVER PRIOR TO PLACING THE UNIT ON THE POLE

BASE COVER PRIOR TO PLACING THE UNIT ON THE POLE

IS NOT NECESSARY.

IS NOT NECESSARY.

2. WHEN PLACING THE UNIT ON THE POLE, FEED THE

2. WHEN PLACING THE UNIT ON THE POLE, FEED THE

SUPPLY LEADS THROUGH THE BASE OF THE UNIT.

SUPPLY LEADS THROUGH THE BASE OF THE UNIT.

NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 2, FEED

NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 2, FEED

THE SUPPLIED PRE-WIRE THROUGH THE POST TOP AND

THE SUPPLIED PRE-WIRE THROUGH THE POST TOP AND

DOWN THE POLE.

DOWN THE POLE.

3. ORIENT THE UNIT SO THAT THE “SS” MARKING ON THE

3. ORIENT THE UNIT SO THAT THE “SS” MARKING ON THE

BASE COVER FACES THE STREET.

BASE COVER FACES THE STREET.

4. TIGHTEN THE THREE MOUNTING SET SCREWS

4. TIGHTEN THE THREE MOUNTING SET SCREWS

WIRING:

WIRING:

N

NOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS

OTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS

SUPPLIED WITH PRE-WIRE.

SUPPLIED WITH PRE-WIRE.

1. REMOVE THE BASE COVER. (SEE

1. REMOVE THE BASE COVER. (SEE

“OPENING AND CLOSING THE UNIT” AND “BASE COVER

“OPENING AND CLOSING THE UNIT” AND “BASE COVER

REMOVAL & INSTALLATION” SECTION.)

REMOVAL & INSTALLATION” SECTION.)

2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE

2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE

INSIDE OF THE BASE.

INSIDE OF THE BASE.

3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT

3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT

THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.

THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.

4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE

4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE

TO THE CASTING BY HOOKING IT AROUND THE HEAD OF

TO THE CASTING BY HOOKING IT AROUND THE HEAD OF

THE GREEN GROUNDING SCREW, LOCATED BESIDE THE

THE GREEN GROUNDING SCREW, LOCATED BESIDE THE

TERMINAL BLOCK, AND TIGHTENING THE SCREW

TERMINAL BLOCK, AND TIGHTENING THE SCREW

SECURELY.

SECURELY.

5. REINSTALL THE BASE COVER.

5. REINSTALL THE BASE COVER.

6. CLOSE THE UNIT.

6. CLOSE THE UNIT.

- IF NO PHOTOCONTROL OPTION WAS SELECTED, A CUSTOMER

- IF NO PHOTOCONTROL OPTION WAS SELECTED, A CUSTOMER

SUPPLIED PHOTOCONTROL WILL NEED TO BE INSTALLED. SEE

SUPPLIED PHOTOCONTROL WILL NEED TO BE INSTALLED. SEE

STEP 1 BELOW.

STEP 1 BELOW.

- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL COME

- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL COME

WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4 BELOW.

WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4 BELOW.

- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH A

- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH A

SHORTING CAP AND THE STEPS BELOW ARE NOT NECESSARY.

SHORTING CAP AND THE STEPS BELOW ARE NOT NECESSARY.

1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND

1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND

LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID

LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID

AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.

AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.

HOWEVER, IT MAY BE REMOVED BY HAND.

HOWEVER, IT MAY BE REMOVED BY HAND.

2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.

2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.

3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A

3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A

VERY AUDIBLE SNAP.

VERY AUDIBLE SNAP.

4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY

4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY

GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND

GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND

TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS

TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS

FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL

FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL

RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS

RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS

THE CUPOLA DOES.

THE CUPOLA DOES.

NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS

NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS

DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.

DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.

DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-

DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-

ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT

ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT

STOPS AND REFUSES TO TURN.

STOPS AND REFUSES TO TURN.

LL ADDER REST INSTALLATION:

ADDER REST INSTALLATION:

NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.

NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.

HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT

HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT

AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT

AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT

(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)

(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)

NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED

NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED

FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE

FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE

POST TOP.

POST TOP.

1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE

1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE

FIGURE 3) INTO THE LADDER REST HOLE LOCATED ON

FIGURE 3) INTO THE LADDER REST HOLE LOCATED ON

THE LEFT AND RIGHT SIDE OF THE LOWER HOUSING JUST

THE LEFT AND RIGHT SIDE OF THE LOWER HOUSING JUST

ABOVE THE MOUNT SET SCREWS.

ABOVE THE MOUNT SET SCREWS.

2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK

2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK

THE LADDER REST INTO THE HOLE. BE SURE TO KEEP

THE LADDER REST INTO THE HOLE. BE SURE TO KEEP

THE LADDER REST LINED UP WITH THE HOLE SO THAT

THE LADDER REST LINED UP WITH THE HOLE SO THAT

THERE SI NO DAMAGE TO THE PIN.

THERE SI NO DAMAGE TO THE PIN.

NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE

NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE

IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT

IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT

AND NUT.

AND NUT.

CAUTION

DO NOT TIGHTEN SET SCREWS

BEYOND 15 ft-lb. TORQUE.

!

CAUTION

THE LADDER REST IS FOR

COSMETIC PURPOSES ONLY. IT

IS NOT INTENDED FOR USE AS

AN ACTUAL REST FOR A LADDER.

!

PHOTOCONTROL:

PHOTOCONTROL:

NOTE: ON THE AVP, NO TOOLING IS NECESSARY FOR THE

NOTE: ON THE AVP, NO TOOLING IS NECESSARY FOR THE

PHOTOCONTROL INSTALLATION OR ADJUSTMENT.

PHOTOCONTROL INSTALLATION OR ADJUSTMENT.

FIGURE 3

FIGURE 3

LADDER REST INSTALLATION

LADDER REST INSTALLATION

PIN

PIN

GENTLY KNOCK HERE

GENTLY KNOCK HERE

FOR INSTALLATION.

FOR INSTALLATION.