beautypg.com

Cfm / static pressure chart, Parts, Gas train – COOK HMD EN User Manual

Page 8

background image

8

Do not enlarge burner ports when clearing a blockage,

performance could be affected.

Replace or tighten any loose or missing fasteners on

the mixing plates. Always use zinc plated or stainless

steel fasteners.

Inspect and clean the flame and spark rod. Occasional

replacement of the flame rod and spark rod may be

necessary to ensure optimum unit performance.

Flame rods can last many years, but because of

thermal expansion of the porcelain, flame rods can fail

over time.

Gas Train

The gas connections, joints and valves should be

checked annually for tightness. Apply a soap and water

solution to all piping; watch for bubbling which indicates a

leak. Other leak testing methods can be used.

CFM / Static Pressure chart

Model #

Low CFM

Low SP

High CFM

High SP

2400

680

0.05

2400

0.94

3400

2000

0.2

3400

1

4100

3000

0.35

4100

1.1

Parts

To replace parts, contact a COOK representative.