2 card data selection options, 1 card types, Card data selection options – HID OMNIKEY 5427 CK Keyboard Wedge User Guide User Manual
Page 9
OMNIKEY Keyboard Wedge Configuration, 5x27-902, Rev D.0
November 2013
Page 9 of 23
HID GLOBAL CONFIDENTIAL AND PROPRIETARY INFORMATION. Use and disclosure of this information is strictly
restricted by the terms of a non-disclosure agreement with HID Global Corporation. If you have received this information and
are not an intended recipient or are not subject to or do not agree to be bound by the terms of the non-disclosure agreement,
please immediately return this document to HID Global Corporation, 15370 Barranca Pkwy, Irvine, CA 92618-3106.
2.2
Card Data Selection Options
The Card Data Selections tab allows setting the keyboard wedge actions once a card is
detected by the reader. Card-in events are customizable depending on the detected card
type.
2.2.1 Card Types
The reader supports the following card types.
•
iCLASS Seos (firmware 03000000 or higher)
•
HID Prox (includes Indala Prox and EM4102 Prox - firmware 03000000 or higher)
•
iCLASS (includes iCLASS SE)
•
MIFARE Classic 1k/4k
•
MIFARE UltraLight /C
•
MIFARE DESFire
•
MIFARE DESFire EV1 (MAC secured, DES/3DES, 3K3DES and AES encrypted -
firmware 02000000 or higher)
•
MIFARE Plus
•
FeliCa (CSN only - firmware 03000000 or higher)
All supported cards are available for configuration in the
Card Type dropdown menu on the
Card Data Selection tab. Default configuration is that all card types are active and preset
data fields are sent upon card detection.
Deselect cards through the web server by selecting the
Enable button on each card page.
The reader ignores card types unchecked on the
Polling Config tab.
Take account of the
Polling Config settings in the Contactless Config menu. Disabling a
card type in the
Card Type dropdown will not prevent the reader from polling for that card
type. De-selecting the card type means that card data will not be sent. The reader polls for all
cards enabled in the
Polling
Config tab. For multi-technology
cards, the card type detected is
dependent on where the reader
is in its polling cycle when the
card is presented.
For card populations involving
multi-technology cards, ensure
the unwanted card type is
switched off in both the
Polling
Config and Card Data