7 dip switch and jumper settings, Dip switch and jumper settings, Table 1: tb1 connector definition – HID MaxiProx Installation Guide User Manual
Page 7: Table 2: tb2 connector definition, Table 3: dip switch and jumper settings, Table 4: interface jumpers description - p3 and p4
MaxiProx
®
Installation Guide
Part No. 5375-901, Rev E.1
March 2012
Page 7 of 19
© 2008-2012 HID Global Corporation. All rights reserved.
Table 1: TB1 Connector Definition
1
2
3
4
5
+DC
Shield
Ground
Ground
Tamper
Common
Tamper
Select
Red
Drain
Black
---
---
Table 2: TB2 Connector Definition
1
2
3
4
5
6
7
8
9
DATA 0
DATA/TD/RX+
DATA 1
CLK/RD/RX
DATA
RTN
GREEN
LED
RED
LED
BEEPER
HOLD/
CARD
PRESENT
TX+
RS422
TX-
RS422
Green
White
Orange
Brown
Yellow
Blue
Note: On TB2, pins 1, 2 and 7 have multiple purposes, depending on the configured reader interface.
In the above table, the first description is for Wiegand, the second for Clock-and-Data, the third for
RS232, and the fourth is for RS422.
2.7 Dip Switch and Jumper Settings
Verify the default settings according to the model ordered, or set the DIP Switches and Jumper
positions according to the following.
Table 3: DIP Switch and Jumper Settings
Switch
Default
Description
1. Interface mode 1
On
2. Interface mode 2
On
3. Interface mode 3
On
4. Beeper control On/Off
On
On - beep after valid card read. Off - no beep after valid
card read.
5. Green LED flash
Off
Off - flash after valid card read. On - no flash after valid
card read.
6. Single/Dual external LED
Off
Off - single line LED control. On - dual line LED control.
7. Serial Baud 1 control
Off
See Table 7: Baud Rate Chart – RS232 and RS422
8. Serial Baud 2 control
Off
See Table 7: Baud Rate Chart – RS232 and RS422
Table 4: Interface Jumpers Description - P3 and P4
P3 and P4
1-2