82000-921, D.1

INSTALLATION GUIDE

7

©2009 - 2012 HID Global Corporation. All rights reserved.

Standard Networked Controller

EH400-K

3.4 Tamper (Reader Interface Board)

The Reader Tamper + and - are implemented allowing a connection for an open collector external tamper from a

reader, such as iCLASS.
Note: Connect P2, Pin 2 (GND) from the Reader Interface Board to the same ground as the reader power, if the reader

is not powered by the units 12 VDC output port.

3.5 Door Interface Board Groups 1 and 2

3.5.1 Group 1

Following are the inputs when the unit is configured for Group 1.

Input

Port

Pin

AC -

P3

Pin3

AC +

P3

Pin 4

BATT -

P3

Pin 5

BATT +

P3

Pin 6

REX -

P3

Pin 7

REX +

P3

Pin 8

Door Mon -

P3

Pin 9

Door Mon +

P3

Pin 10

3.5.2 Group 2

Following are the inputs when the unit is configured for Group 2.

Input

Port

Pin

Input 4 -

P3

Pin3

Input 4 +

P3

Pin 4

Input 3 -

P3

Pin 5

Input 3 +

P3

Pin 6

Input 2 -

P3

Pin 7

Input 2 +

P3

Pin 8

Input 1 -

P3

Pin 9

Input 1 +

P3