beautypg.com

Step 3 - analyze power requirements, Edge evo hi-o networked controller – HID EDGE EVO EH400 Hi-O Controller Installation Guide User Manual

Page 3

background image

82000-920 C.0

INSTALLATION GUIDE

3

©2009 - 2011 HID Global Corporation. All rights reserved.

EDGE EVO Hi-O Networked Controller

EH400

Step 3 - Analyze Power Requirements

A - Door Peripheral Operational Currents

For the door peripherals identified in “Step 1 - Identify System Components” on page 2, consult the vendor data

sheets to determine the operational current draw. Typical operational current draw is provided below.
Note: See individual peripheral data sheets for actual operational current draw.

Device

Conditions

Typical Operational Current

Door Position Switch

V

in

= 12VDC

15mA

(For example, Securitron MSS) V

in

= 24VDC

15mA

Mag Lock

V

in

= 12VDC

300mA

(For example, Securitron M32)

V

in

= 24VDC

150mA

REX Switch

V

in

= 12VDC

28mA

(For example, Securitron EEB)

V

in

= 24VDC

38mA

Exit Alarm
(For example, Detex 411)

V

in

= 12VDC

V

in

= 24VDC

70mA
70mA

iCLASS Wiegand Reader

V

in

= 12VDC

150mA

Consult HID datasheets for Hi-O enabled interface devices.

B - Match I/O Requirements to the Hi-O Interface Device

For the door peripherals identified in “Step 1 - Identify System Components” on page 2, the system requires

connection to a Hi-O interface device. In this example, the EDGE EVO Hi-O Edge Door Module (EDM-M) provides

general purpose I/O connectivity.
The Hi-O iCLASS reader does not require connection to the EDM-M and derives power and data connectivity from the

Hi-O CANbus directly.

Device

Ports

Conditions

I

out

EDGE EVO Hi-O Door

Module EDM-M

Strike / Aux

NC or NO

DC Output

+12VDC unregulated (@+12VDC EDM-M input)

700mA*

+24VDC unregulated (@+24VDC EDM-M input)

700mA*

+12VDC regulated (@+24VDC EDM-M input)

310 mA*

Dry Jumpers

+12 to +24VDC External

2.00 Amp**

* Shared between each relay
** Each relay

The combined current requirement for the four door peripherals identified in “Step 1 - Identify System Components” on

page 2 is 413mA @ +12VDC,

or 273mA @ +24VDC.
The EDM-M provides sufficient power when the door peripherals are connected to the Strike/AUX relays configured for

unregulated output at +12VDC/+24VDC. Alternatively, connect the door peripherals to the Strike/AUX relays configured

for Dry contact.
The Hi-O iCLASS reader does not require connection to the EDM-M and derives power and data connectivity from the

Hi-O CANbus directly.