Step 3 - analyze power requirements, Edge evo hi-o networked controller – HID EDGE EVO EH400 Hi-O Controller Installation Guide User Manual
Page 3
82000-920 C.0
INSTALLATION GUIDE
3
©2009 - 2011 HID Global Corporation. All rights reserved.
EDGE EVO Hi-O Networked Controller
EH400
Step 3 - Analyze Power Requirements
A - Door Peripheral Operational Currents
sheets to determine the operational current draw. Typical operational current draw is provided below.
Note: See individual peripheral data sheets for actual operational current draw.
Device
Conditions
Typical Operational Current
Door Position Switch
V
in
= 12VDC
15mA
(For example, Securitron MSS) V
in
= 24VDC
15mA
Mag Lock
V
in
= 12VDC
300mA
(For example, Securitron M32)
V
in
= 24VDC
150mA
REX Switch
V
in
= 12VDC
28mA
(For example, Securitron EEB)
V
in
= 24VDC
38mA
Exit Alarm
(For example, Detex 411)
V
in
= 12VDC
V
in
= 24VDC
70mA
70mA
iCLASS Wiegand Reader
V
in
= 12VDC
150mA
Consult HID datasheets for Hi-O enabled interface devices.
B - Match I/O Requirements to the Hi-O Interface Device
connection to a Hi-O interface device. In this example, the EDGE EVO Hi-O Edge Door Module (EDM-M) provides
general purpose I/O connectivity.
The Hi-O iCLASS reader does not require connection to the EDM-M and derives power and data connectivity from the
Hi-O CANbus directly.
Device
Ports
Conditions
I
out
EDGE EVO Hi-O Door
Module EDM-M
Strike / Aux
NC or NO
DC Output
+12VDC unregulated (@+12VDC EDM-M input)
700mA*
+24VDC unregulated (@+24VDC EDM-M input)
700mA*
+12VDC regulated (@+24VDC EDM-M input)
310 mA*
Dry Jumpers
+12 to +24VDC External
2.00 Amp**
* Shared between each relay
** Each relay
The combined current requirement for the four door peripherals identified in “Step 1 - Identify System Components” on
page 2 is 413mA @ +12VDC,
or 273mA @ +24VDC.
The EDM-M provides sufficient power when the door peripherals are connected to the Strike/AUX relays configured for
unregulated output at +12VDC/+24VDC. Alternatively, connect the door peripherals to the Strike/AUX relays configured
for Dry contact.
The Hi-O iCLASS reader does not require connection to the EDM-M and derives power and data connectivity from the
Hi-O CANbus directly.