Troubleshooting – Blodgett SN-E Series User Manual
Page 16
14
OM-SN-E
Troubleshooting
This steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to
make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the check list is marked with
(x), it means that the work should be done by a factory authorized service representative.
SYMPTOM
WHO
WHAT TO CHECK
Steam generator does not
fill with water.
User
a. Is the ON switch depressed?
b. Is the water supply connected?
c. Is the water turned on?
d. Check for low water pressure (less than 30 PSI) or low water flow (less than 1.5
gpm).
e. Is the screen at the water connection clogged?
f. Has the steam generator been de-limed?
No steam.
User
a. Is the ON switch depressed?
b. Is the water supply connected?
c. Is the water turned on?
d. Are steamer doors completely closed?
e. Is the steam generator blocked with lime build-up?
DELIME light comes on
after four minutes.
User
a. Is the water supply connected and adequate?
b. Is the water turned on?
c. Has the unit been de-limed? (Refer to Cleaning Section)
Excessive steam escaping from
rear of unit.
User
a. Is the water spray hose kinked or obstructed?
Auth Service
Rep Only
b. Is the water spray solenoid connected?(x)
c. Is the drain properly vented? (x)