Operation
A. Controls
Operator controls are on the front right of the unit.
The control panels have the following touch pads and indicator lights:
1. The ON/OFF touch pad gets the steamer ready for use, or shuts it off.
2. The READY indicator light shows that the steam generator is at standby
temperature and the cavity is hot enough to begin steaming.
3. When one probe is covered with lime scale or fails, the DELIME light
flashes briefly every few seconds, but the unit will continue to operate. De-
lime the unit as soon as possible. The DELIME light will flash until power is
removed from the unit, or the unit goes through a clean cycle.
4. If the problem continues, both probes may fail. Then the steamer
stops working, and the SERVICE light is lit. If DELIMING/CLEANING
does not correct, turn off the power and contact an Authorized Service
Representative for repair.
5. The DELIME indicator light is lit when the unit is operating in the cleaning
mode.
6. The HI TEMP indicator light comes on when the steam generator is too hot.
The unit will automatically shut off, and cannot be turned on again until the
steam generator cools and the HI TEMP indicator light goes out.
7. The TIMING indicator light stays on when the timer is running.
8. The CLEAN touch pad is used to start the automatic 50 minute cleaning
cycle.
9. The timer is used in three ways:
1. In the OFF position the steam generator stays at a low boil or
“holding” temperature.
2. When a cook time is set, the unit steams until the timer runs down to
OFF. At that time steaming stops, a red light comes on and a beeper
sounds.
3. With the timer turned to the ON position, the unit steams continuously.
The green light stays lit. The steamer will not time down.
DONE light
Manual ON light
STEAMER light
TIMING indicator light
ON/OFF touch pad
POWER indicator light
READY indicator light
SERVICE indicator light
DELIME indicator light
CLEAN cycle touch pad
HIGH TEMP
indicator light
WARNING
ANY POTENTIAL USER OF THE EQUIPMENT
MUST BE TRAINED IN SAFE AND CORRECT
OPERATING PROCEDURES.