AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide
63
" 12
PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and
shall be easily accessible.
" 13
CAUTION: Air vents must not be blocked and must have free access to the room
ambient air for cooling.
" 14
OPERATING TEMPERATURE: This product is designed for a maximum ambient
temperature of 40° degrees C.
" 15
ALL COUNTRIES: Install product in accordance with local and National Electrical
Codes.
" 16
WARNING: For centralized dc power connection, install only in a restricted access
area.
" 17
A tray cable is required to connect the power source if the unit is powered by
centralized DC power. The tray cable must be UL listed Type TC tray cable and rated
at 600 V and 90 degree C, with three conductors, minimum 14 AWG.
" 18
WARNING: Only trained and qualified personnel are allowed to install or replace this
equipment.
" 19
WARNING: As a safety precaution, a 10 Amp circuit breaker should be installed at the
supply end of the cable to be used with this LAN equipment.
ALWAYS connect the wiring to the LAN equipment first before connecting the
wiring to the breaker. To avoid the danger of physical injury from electrical shock, do
not work with HOT feeds. Always be sure that the breaker is in the OFF position
before connecting the wiring to the breaker.
" 20
WARNING: Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by leaving exposed
wire on the terminal block after installation.
" 21
WARNING: When installing this equipment, always ensure that the frame ground
connection is installed first and disconnected last.
" 22
WARNING: "Safety Hazard"- Check to see if there are any exposed copper strands
coming from the installed wires. When this installation is done correctly there should
be no exposed copper wire strands extending from the terminal block. Any exposed
wiring can conduct harmful levels of electricity to persons touching the wires.
" 23
This system will work with a positive grounded or negative grounded DC system.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
" 1
Hochfrequenzstörung
EN55022 Klasse A
" 2
WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen
ergreifen.
" 3
Störsicherheit
EN50082-1 1997
" 4
Elektrische Sicherheit
EN60950, UL 1950, CSA 950
" 5
Laser
EN60825
SICHERHEIT
" 6
WARNUNG Laserprodukt der Klasse 1.
" 7
WARNUNG Nicht direkt in den Strahl blicken.