Network Management and SNMP Commands
Command
Description
clear session
Terminates a Telnet session from the switch.
config snmp add
Adds the IP address of an SNMP management station to the access
list. Up to 32 addresses can be specified.
config snmp add trapreceiver
community
Adds the IP address of a specified trap receiver. The IP address can
be a unicast, multicast, or broadcast. A maximum of six trap
receivers is allowed.
config snmp community [readonly |
readwrite]
Adds an SNMP read or read/write community string. The default
readonly
community string is
public
. The default
readwrite
community string is
private
. Each community string can have a
maximum of 126 characters, and can be enclosed by double
quotation marks.
config snmp delete [
all]
Deletes the IP address of a specified SNMP management station or
all SNMP management stations. If you delete all addresses, any
machine can have SNMP management access to the switch.
config snmp delete trapreceiver
[
Deletes the IP address of a specified trap receiver or all authorized
trap receivers.
config snmp syscontact
Configures the name of the system contact. A maximum of 255
characters is allowed.
config snmp syslocation
Configures the location of the switch. A maximum of 255 characters
is allowed.
config snmp sysname
Configures the name of the switch. A maximum of 32 characters is
allowed. The default sysname is the model name of the device (for
example,
9108)
. The
sysname
appears in the switch prompt.
disable idletimeout
Disables the timer that disconnects all sessions. Once disabled,
console sessions remain open until the switch is rebooted or you
logoff. Telnet sessions remain open until you close the Telnet client.
disable rmon
Disables the collection of RMON statistics on the switch.
disable snmp access
Disables SNMP on the switch. Disabling SNMP access does not affect
the SNMP configuration (for example, community strings).
disable snmp traps
Prevents SNMP traps from being sent from the switch. Does not
clear the SNMP trap receivers that have been configured.
disable telnet
Disables Telnet access to the switch.
disable web
Disables Web access to the switch.
enable idletimeout
Enables a timer that disconnects all sessions (both Telnet and
console) after 20 minutes of inactivity. The default setting is
disabled.
enable rmon
Enables the collection of RMON statistics on the switch.
enable snmp access
Turns on SNMP support for the switch.
enable snmp traps
Turns on SNMP trap support.
enable telnet
Enables Telnet access to the switch.
enable web
Enables Web access to the switch.
logout | quit