Allied Telesis AT-S63 User Manual
Page 113

AT-S63 Management Software Command Line Interface User’s Guide
113
100mfull
100 Mbps and full-duplex mode.
Note
A speed of 1000 Mbps is only available when you set the port to
autonegotiate.
Note
When a transceiver is inserted into an uplink slot and a link is
established, that slot becomes a primary uplink port and the
corresponding backup port, 23R or 24R, automatically transitions to
redundant uplink status. The speed and duplex mode of the
redundant port automatically transitions to autonegotiate to match
the speed of the primary uplink port and you cannot configure the
MDI/MDIX crossover parameter.
mdimode
Sets the wiring configuration of the port. This
parameter applies only to twisted pair ports, and
only when a port’s speed and duplex mode are set
manually. If a port is autonegotiating its speed and
duplex mode, the MDI/MDIX setting is established
automatically and cannot be changed. The options
are:
mdi
Sets the port’s configuration to MDI.
mdix
Sets the port’s configuration to MDI-X.
renegotiation
Prompts the port to renegotiate its speed and
duplex mode with the end node. This parameter
only works when the port is using autonegotiation.
The only option is:
auto Renegotiates
speed and duplex mode
with the end node.
flowcontrol
Specifies the flow control on the port. Flow control
applies only to ports operating in full duplex mode.
When flow control is activated, a port sends out a
PAUSE packet whenever it wants the end node to
stop sending packets. The options are:
disabled No
flow
control. This is the default
setting.
enabled
Flow control is activated.