beautypg.com

Campbell Scientific PC400 Datalogger Support Software User Manual

Page 247

background image

Appendix C. Log Files and the LogTool Application

TABLE C-1. Transaction Log Messages

Code

Message Text

Message Parameters

Message Meaning

User Response to
Message

105 BMP1

packet

received

The packet message type
code:
0 Packet Delivery Fault
Notification
1 Status/Warning/Fault
Notification
2 Network Description
Transaction
3 Clock Check/Set
Transaction
4 Program Down-load
Transaction
5 Program Up-load
Transaction
7 Data Advise Command
Transaction
8 Data Advise Notification
Packet
9 Hole Collection
Command Transaction
10 Control Command (Set
Variable) Transaction
11 User I/O Transaction
(Terminal Mode)
12 Memory Image Down-
load Transaction
13 Memory Image Up-load
Transaction
14 Get Table Definitions
Transaction
15 RF Test Transaction
16 Communication Status
Notification

The specified BMP1
packet was received
over the serial
communications link.
The number indicates
the type of message
received.

106 Data

file

output

failed

Data collected from a
datalogger could not
be written to the data
output file.

Check that there is
space available on the
hard disk and that write
permissions allow the
server to write the data
output files.

107

Max time on-
line exceeded

The amount of time the
device was connected, in
milliseconds

A client kept the
communication link
on-line longer than
the specified max
time on-line.

108

Table reset

The name of the table that
was reset; The account
name of the logged in
client

The name of a table
was changed at the
request of a client.
On CR1000,
CR5000, and
CR9000 loggers this
is a reset for the table
in the datalogger and
on the PC.

C-13