Campbell Scientific PC400 Datalogger Support Software User Manual
Page 244

Appendix C. Log Files and the LogTool Application
TABLE C-1. Transaction Log Messages
Code
Message Text
Message Parameters
Message Meaning
User Response to
Message
88
Manual poll
aborted
The
manual
poll
operation was
stopped or failed to
complete due to
communications
failure or a timeout.
Check communications
with the datalogger by
trying to check the
clock. If that fails,
follow the steps for
message 14.
89
Selective
manual poll
begun
Collect area name
A user specified poll
has been started for
one of the datalogger
collect areas.
90
Selective
manual poll
complete
Collect area name
The user specified
manual poll has
completed.
91
Selective
manual poll
aborted
Collect area name
The user specified
manual poll failed.
Check communications
with the datalogger by
trying to check the
clock. If that fails,
follow the steps for
message 14.
92
Polling started
on collect area
Collect area name
Data has been
requested for the
specified collect area.
This message is
always associated
with another message
indicating whether
this is scheduled,
manual or selective
manual polling.
Collect areas can be
table for table mode
dataloggers, final
storage areas, ports and
flags, or input locations.
93
Collect area
poll data
Collect area name
Data has been
received from an
array based
datalogger for the
specified collect area.
94
Collect area
polling
complete
Collect area name
Data collection for
the specified collect
area has successfully
completed.
95
Collect area
polling failed
Collect area name
Data collection for
the specified collect
area failed.
Check communications
with the datalogger by
trying to check the
clock. If that fails,
follow the steps for
message 14.
99
Collect area
first poll
This message is
posted either the first
time data is collected
for a collect area, or
holes were lost for
the datalogger.
If this is not the first
poll for the collect area,
this message indicates
that data that had been
stored in the datalogger
was lost before it could
be collected.
C-10