Campbell Scientific PC208 Datalogger Support Software User Manual
Page 77

SECTION 5. TELCOM
5-3
Station File Name: MTNTOP
Datalogger or Command Type:
CR10X
Security Code: 0
Fix Datalogger Clock Using PC Clock:
No
Final Storage Area to Collect From:
1st Area
Data Collection Method:
Since Last Call;Append File;
Nbr of Arrays to Backup on First Call:
0
Data File Format:
Comma Separated ASCII
Primary Call Interval (minutes):
1440
Recovery Call Interval #1 (minutes):
15
Repetitions of Recovery Interval #1:
4
Recovery Call Interval #2 (minutes):
1440
Maximum Time Call Will Take (minutes):
10
Next Time To Call:
3/27/92 0:02:00
Interface Devices:
COM1 Baud Rate: 1200
^O = Save/Resume
^P = Save/Done
ESC = Abandon Edit
TABLE 5-2. TELCOM Editing Commands
CURSOR MOVEMENT:
char left .......................................................................................... Ctrl S or left arrow
char right ........................................................................................ Ctrl D or right arrow
word or entry left ............................................................................ Ctrl A or left arrow
word or entry right .......................................................................... Ctrl F or right arrow
line or entry up ............................................................................... Ctrl E or up arrow
line or entry down........................................................................... Ctrl X or down arrow
page up in array or previous screen .............................................. Ctrl R or PgUp
page down in array or next screen................................................. Ctrl C or PgDn
left side of entry or screen ............................................................. Ctrl QS
right side of entry or screen ........................................................... Ctrl QD
end of screen ................................................................................. End
beginning of screen ....................................................................... Home
DELETE COMMANDS:
delete char left ............................................................................... Ctrl H or BS
delete current char ......................................................................... Ctrl G or Del
delete current word or entry ........................................................... Ctrl T
delete interface device from an already existing list ...................... Ctrl Y
END EDIT COMMANDS:
save and resume where you were ................................................. Ctrl O
save and advance to next part of program .................................... Ctrl P
abandon edit and go to previous valid state .................................. Esc
MISC. EDITING COMMANDS:
Insert interface device to already existing list ................................ Ctrl N
Enter & advance to next parameter ............................................... CR
Converted to a space..................................................................... TAB
Display hidden menu option on menu entries only ........................ H or Ctrl H