beautypg.com

Appendix f. frequently asked questions, F.1 pc208e.exe, F.2 edlog.exe – Campbell Scientific PC208 Datalogger Support Software User Manual

Page 127

background image

F-1

APPENDIX F. FREQUENTLY ASKED QUESTIONS

F.1 PC208E.EXE

Why does the mouse stop working in
monitor mode(s)?

The monitor mode screens do not support the
mouse.

What’s with these “INI” files?

PC208E uses an PC208E.INI file to remember
the Station or Script file you used last. PC208E
will reload the file automatically when PC208E
is restarted. PC208E looks for its INI file in the
following sequence:

Looks in the current directory

Looks in the directory where the
PC208E.EXE file is located

PC208E stops looking when it finds an INI file.

PC208E updates the INI file it found when you
exit PC208E. If PC208E did not find an INI file
it will creates one in the current directory.

When should I use GT.EXE or TELCOM.EXE
instead of PC208E.EXE?

Script and stations files as used by TELCOM
and GT are compatible with PC208E. GT and
TELCOM may support some older hardware
that PC208E does not.

GT.EXE retains compatibility with previous
versions supporting command line parameters;
PC208E.EXE does not support command line
parameters beyond specifying a station file. In
addition GT.EXE uses a simple menu which
laptop users (no mouse) may prefer.

TELCOM.EXE should be used when a script file
is started from a DOS batch file. For example,
to start a script file in the AUTOEXEC.BAT file
use TELCOM