Table of Contents

7.6.3

Edlog Programming ................................................................... 29

7.7

Operation in High Sediment Loads and Sandy Sediments ................ 30

7.7.1

Wiper Removal Procedure ......................................................... 31

8.

Factors that Affect Turbidity and Suspended-

Sediment Measurements ....................................... 33

8.1

Particle Size ....................................................................................... 33

8.2

Suspensions with Mud and Sand ....................................................... 34

8.3

Particle-Shape Effects ....................................................................... 34

8.4

High Sediment Concentrations .......................................................... 35

8.5

IR Reflectivity—Sediment Color ...................................................... 36

8.6

Water Color ....................................................................................... 37

8.7

Bubbles and Plankton ........................................................................ 37

9.

Maintenance .............................................................. 38

10.

Troubleshooting ........................................................ 39

11.

References ................................................................. 41

Appendices
A.

Importing Short Cut Code ...................................... A-1

A.1

Importing Short Cut Code into a Program Editor ............................ A-1

A.1.1

CRBasic Datalogger ................................................................. A-1

A.1.2

Edlog ........................................................................................ A-2

B.

Example Programs .................................................. B-1

B.1

CR1000 SDI-12 Program ................................................................ B-1

B.2

CR1000 RS-232 Program ................................................................ B-2

B.3

CR1000 Analog Program ................................................................ B-3

B.4

Examples for High Sediment Loads ................................................ B-4

B.4.1

Normally Open CR1000 Example ............................................ B-4

B.4.2

Cycle Shutter/Wiper for Each Measurement CR1000

Program ................................................................................ B-5

C.

OBS500 Copper Sleeve Kit Installation ................. C-1

Figures

4-1. Use strain relief to keep stress off the cable and provide extra

security ............................................................................................. 3

4-2. Apply tape to protect sensor ................................................................ 4

4-3. Secure with hose clamps. Do not overtighten. ................................... 4

4-4. Place and secure mounting fixture ....................................................... 5

5-1. Drawing of the OBS500 sensor ......................................................... 10

5-2. Orientation of emitter cone (source beam) and OBS and side

scatter detector (acceptance) cones ................................................ 11

7-1. Device Configuration Utility ............................................................. 14

7-2. Terminal Mode using 1 and H commands ......................................... 15

ii