7.5 Diagnostic LED Indicators Within the Enclosure


Two green LEDs labelled "LASER ON" and "STATUS" are visible on the DSP
(see Fig 7.3). Their function is as follows:-

"LASER ON" LED:-
Off = laser off
Flashing = laser fault
On = laser on

"STATUS" LED

1 flash every 10 seconds = OK

2 flashes every 10 seconds = warning (possible degraded performance)

3 flashes every 10 seconds = alarm (measurements not possible)


The DSP "STATUS" LED duplicates the LED visible through the top window.

There is a red LED on the PSU. It will give 0.5 second flashes as follows:-

1 flash every 10 seconds = PSU OK

2 flashes every 10 seconds = running in battery mode
3 flashes every 10 seconds = no communications to the DSP. This
takes 60 seconds to start after a communications failure.


Fig 7.3 Diagnostic LED indicators

There is a red LED on the Laser module

Off = Laser off

On = Laser on