43

LINE 6
ETX CRC16 EOT CR LF

where

ETX = End-of-Text character
CRC16 (4 characters) = CRC16-CCITT Checksum
EOT

= End-of-Transmission character

CR LF

= Carriage Return + Line Feed

6.3 CL31 Messages


MESSAGES 101 - 106, (CL31 MESSAGE 1)

LINE 1
SOH CL ID OS 1 Samples ETX CR LF

where

SOH = Start-of-Heading character

CL = Always CL

ID
= A single ASCII character, 0-9, a - z or A - Z, case sensitive. Default ID = 0

OS
= Operating system, 100 ... 999

1 = Always 1

Samples = backscatter resolution and number of samples

1 = MESSAGE 101, 10 m x 770 samples, range 7700 m
2 = MESSAGE 102, 20 m x 385 samples, range 7700 m
3 = MESSAGE 103, 5 m x 1500 samples, range 7500 m
4 = MESSAGE 104, 5 m x 770 samples, range 3850 m
5 = MESSAGE 105, no backscatter profile
6 = MESSAGE 106, extended range, 5 m x 2048 samples, range 10,240 m

ETX = End-of-Text Character

CR LF

= Carriage Return + Line Feed