beautypg.com

Campbell Scientific CS135 Lidar Ceilometer User Manual

Page 39

background image

User Guide

31

1 = One cloud base detected
2 = Two cloud bases detected
3 = Three cloud bases detected
4 = Four cloud bases detected
5 = Full obscuration determined but no cloud base detected
6 = Some obscuration detected but determined to be transparent
/ = Raw data input to algorithm missing or suspect

WA (1 character) = Warning or alarm status:

0 = No alarm or warning
W = Warning
A = Alarm

tr (3 characters) = Window transmission, %

h1 (5 characters) = 1st Height
If detection status is 1, 2, 3 or 4 h1 = Lowest cloud base reported
If detection status is 5 h1 =

 

Vertical visibility as calculated

If detection status is 0 or 6 h1 =

 

"/////"


h2 (5 characters) = 2nd Height
If detection status is 2, 3 or 4 h2 = Second highest cloud base reported
If detection status is 5 h2 =

 H

ighest signal received

If detection status is 0, 1, or 6 h2 =

 

"/////"


h3 (5 characters) = 3rd Height
If detection status is 3 or 4 h3 = Third highest cloud base reported
If detection status is 0, 1, 2, 5 or 6 h3 =

 

"/////"


h4 (5 characters) = 4th Height
If detection status is 4 h4 = Highest cloud base reported
If detection status is 0, 1, 2, 3 or 5 h4 = "/////"

flags (12 characters in 3 groups of 4, space separated) = Alarm or warning information

Description of the most significant alarm word (left side, bits going left to right). Each alarm word is a
hexadecimal sum of all the error bits.
Bit Description
8000 XXXX XXXX

Units. Feet = 0, metre = 1.

4000 XXXX XXXX

Reserved for future use

2000 XXXX XXXX

Reserved for future use

1000 XXXX XXXX

Reserved for future use

0800 XXXX XXXX

Reserved for future use

0400 XXXX XXXX

Laser shut down due to operating temperature out of range

0200 XXXX XXXX

The lead acid battery voltage is reading low

0100 XXXX XXXX

Mains supply has failed (Required a PSU to be present)

0080 XXXX XXXX

The external heater blower assembly temperature is out of bounds

0040 XXXX XXXX

External heater blower failure

0020 XXXX XXXX

The PSUs internal temperature is high

0010 XXXX XXXX

PSU OS has failed its signature check

0008 XXXX XXXX

No communications between DSP and PSU