Section 2. specifications, Specifications -1 – Campbell Scientific CC5MPX and CC5MPXWD Digital Network Cameras User Manual
Page 13

2-1
Section 2. Specifications
CC5MPXWD Heating
Element Resistance: 18
Ohms
Operating Power
CC5MPX:
9 to 30 Vdc
CC5MPXWD:
9 to 16 Vdc
Operating the CC5MPXWD camera and defroster at
voltages higher than 16 Vdc may damage the camera.
Current Drain
Operating (camera only):
250 mA maximum @ 12 Vdc
Quiescent:
≤1 mA (off power mode)
CC5MPXWD defroster on: 1.2 A (maximum @ 16 Vdc);
1 A (typical @ 12 Vdc)
Operating Temperature: -40
° to +60°C
Clock Accuracy:
±2 minutes/year (-40
° to 60°C)
Lens
Mount: C-type
IRIS: DC
compatible
Standard Lens:
4 to 12 mm, 27° to 80° field of view (FOV)
Zoom Lens:
10 to 40 mm, 9° to 35° FOV (ordered as a
special; contact Campbell Scientific for more
information)
Image or Video
Capture Triggers:
Two independent self timers
Motion
detection
Web page control
External trigger
Still Image Resolution (JPEG): 2592x1944 640x352
1280x960
320x240
1280x720
320x176
640x480
Video:
Capable of 720P - 1280x720 (MPEG4),
640x480 (Live Video Only/MJPEG),
320x240 (MPEG4)
Ext. Input Signal
Logic Low Level:
<0.65 V (-20 Vdc absolute minimum)
Logic
High
Level:
>2.0 Vdc (+20 Vdc absolute maximum)
Minimum
Pulse
Width: 10
ms
Communication Interfaces: Ethernet
10/100
RS-232
port
RS-485
port
CAUTION