beautypg.com

Section 2. specifications, Specifications -1 – Campbell Scientific CC5MPX and CC5MPXWD Digital Network Cameras User Manual

Page 13

background image

2-1

Section 2. Specifications

CC5MPXWD Heating
Element Resistance:
18

Ohms


Operating Power
CC5MPX:

9 to 30 Vdc

CC5MPXWD:

9 to 16 Vdc

Operating the CC5MPXWD camera and defroster at
voltages higher than 16 Vdc may damage the camera.

Current Drain
Operating (camera only):

250 mA maximum @ 12 Vdc

Quiescent:

≤1 mA (off power mode)

CC5MPXWD defroster on: 1.2 A (maximum @ 16 Vdc);

1 A (typical @ 12 Vdc)


Operating Temperature: -40

° to +60°C


Clock Accuracy:

±2 minutes/year (-40

° to 60°C)


Lens
Mount:
C-type
IRIS: DC

compatible

Standard Lens:

4 to 12 mm, 27° to 80° field of view (FOV)

Zoom Lens:

10 to 40 mm, 9° to 35° FOV (ordered as a

special; contact Campbell Scientific for more

information)


Image or Video
Capture Triggers:

Two independent self timers

Motion

detection

Web page control

External trigger


Still Image Resolution (JPEG): 2592x1944 640x352

1280x960

320x240

1280x720

320x176

640x480


Video:

Capable of 720P - 1280x720 (MPEG4),
640x480 (Live Video Only/MJPEG),
320x240 (MPEG4)


Ext. Input Signal
Logic Low Level:

<0.65 V (-20 Vdc absolute minimum)

Logic

High

Level:

>2.0 Vdc (+20 Vdc absolute maximum)

Minimum

Pulse

Width: 10

ms


Communication Interfaces: Ethernet

10/100

RS-232

port

RS-485

port

CAUTION