XLT103-10

Specifications / Installation


Section 3 continued





























4

DIP Switches, Wiring and Jumpers


Wire according to the type of inputs / outputs used and select the appropriate jumper
option.































4.1.

I/O Jumper Setting (JP1)






















4.2.

DIP Switch Settings (RS-485)












4.3. Wiring

Examples





J1

Orange

XT103-10

Name

I1 IN1
I2 IN2
I3 IN3
I4 IN4
I5 IN5
I6 IN6
I7 IN7
I8 IN8

H1

HSC1 / IN9

H2

HSC2 / IN10

H3

HSC3 / IN11

H4

HSC4 / IN12

A1 Thermistor

1

A2 Thermistor

2

0V Ground




J2

Black

XE103-10

Name

0V Ground
V+ V+

*

NC No

Connect

Q12 OUT12
Q11 OUT11
Q10 OUT10

Q9 OUT9
Q8 OUT8
Q7 OUT7
Q6 OUT6
Q5 OUT5
Q4 OUT4
Q3 OUT3
Q2

OUT2 / PWM2

Q1

OUT1 / PWM1

V+* Supply for Sourcing Outputs





8

1

Pin

MJ1 Pins

MJ2 Pins

8

TXD OUT TXD OUT

7

RXD IN RXD IN

6

0

V Ground 0

V Ground

5

NC

No

Connect

NC

No

Connect

4

RTS OUT TX- OUT

3

CTS IN TX+ OUT

2

RX- /

TX-

IN /

OUT

RX- IN

1

RX+ /

TX+

IN /

OUT

RX+ IN

Note:

The Cscape Module Setup configuration must match

the selected I/O (JP) jumper settings.

I1

0V

001XLE036

12-24VDC

I1

0V

Positive Logic In Negative Logic In

Positive Logic vs. Negative Logic Wiring

The XLE can be wired for Positive Logic inputs or

Negative Logic inputs.

Factory Use

(default – none)

MJ2 Termination

(default – none)

MJ1 Termination

(default – none)

As seen when looking at the top of the XLT unit.

Memory Slot:
Uses Removable Memory for data logging, screen
captures, program loading and recipes.
Horner Part No.: HE-MC1

Serial Communications:
MJ1

: (RS-232 / RS-485) Use for Cscape programming and

Application-Defined Communications.

MJ2:

(RS-232 / RS-485) Use for Application-Defined

Communications.

Location of I/O jumper (JP1)

and wiring connectors

(J1 & J2).

Wiring Specifications

Š

For I/O wiring (discrete), use the

following wire type or equivalent:
Belden 9918, 18 AWG or larger.

Š

For shielded Analog I/O wiring,

use the following wire type or
equivalent: Belden 8441, 18
AWG or larger.

Š

For CAN wiring, use the

following wire type or equivalent:
Belden 3084, 24 AWG or larger.

The DIP Switches are used for
termination of the RS-485 ports. The
XLE is shipped unterminated.


To terminate, select one of the DIP
Switches and configure it based upon
the option that is desired.

Negative Logic

Positive Logic

JP1 Digital DC Inputs

Default

Q1

Q2

Q3

Q4

Q9

Q10

Q11

Q12

Q5

Q6

Q7

Q8

V+

0V

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

10 - 30VDC

Q13

001XLE024

LOAD

XT103-10 J2 Black

Positive Logic

Digital Out

Note:

The wiring examples show

Positive Logic

input wiring.

I1

I2

I3

I4

0V

I5

I6

I7

I8

H1

001XLE061

12-24VDC

A1

A2

H2

H3

H4

T

T

J1

J2

JP1

001XLE060

XT103-10 J1 Orange

Positive Logic

Digital In

001XLE037-R1