beautypg.com

Red Lion PAXLRT User Manual

Model paxlrt - pax lite rtd meter, Cc us listed us listed, General description

background image

1



ACCEPTS STANDARD 3-WIRE 100

RTD SENSORS (ALPHA =

0.00385 or ALPHA = 0.00392)



CONFORMS TO ITS-90 STANDARDS



SELECTABLE °F OR °C WITH 0.1 OR 1 DEGREE DISPLAY

RESOLUTION



STATE-OF-THE-ART DIGITAL ELECTRONICS FOR GREATER

ACCURACY AND RELIABILITY



FULL 4-DIGIT, HIGH VISIBILITY, 0.56" (14.2 mm) HIGH RED LED

DISPLAY



PROGRAMMABLE TEMPERATURE OFFSET



PROGRAMMABLE DIGITAL FILTERING



PEAK/VALLEY (HI/LO READING) MEMORY



NEMA 4X/IP65 SEALED FRONT BEZEL



CUSTOM UNITS OVERLAY WITH BACKLIGHT

GENERAL DESCRIPTION

The Pax Lite RTD Meter accepts standard RTD inputs and precisely linearizes

them into temperature readings. A full 4-digit display accommodates a wide
range of temperature inputs. State-of-the-art digital circuitry virtually eliminates
errors due to drift.

The meter features a readout choice of either Fahrenheit or Celsius with 0.1 or

1 degree resolution. English Style display prompts and front panel buttons aid the
operator through set-up and operation. Programmable digital filtering enhances
the stability of the reading. All set-up data is stored in EEPROM, which will hold
data for a minimum of 10 years without power.

The meter provides a Peak (HI) and Valley (LO) reading memory with

selectable capture delay time. The capture delay is used to prevent detection of
false Peak or Valley readings that may occur during start-up or unusual process
events. The Peak and Valley readings are stored at power-down to allow
monitoring the process limits over any length of time (shifts, days, etc.).

The meter has several built-in diagnostic functions to alert operators of any

malfunction. Extensive testing of noise interference mechanisms and full burn-in
makes the meter extremely reliable in industrial environments. The front bezel
meets NEMA 4X/IP65 requirements for wash down applications.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired. Do not use this unit to directly
command motors, valves, or other actuators not equipped with safeguards. To
do so, can be potentially harmful to persons or equipment in the event of a fault
to the unit.

DEFINITION OF TERMS

INSTALLATION CATEGORY (overvoltage category) I:

Signal level, special equipment or parts of equipment, telecommunication,
electronic, etc. with smaller transient overvoltages than Installation
Category (overvoltage category) II.

INSTALLATION CATEGORY (overvoltage category) II:

Local level, appliances, portable equipment, etc. with smaller transient
overvoltages than Installation Category (overvoltage category) III.

MODEL PAXLRT - PAX LITE RTD METER

CAUTION: Risk of Danger

Read complete instructions prior to

installation and operation of the unit.

CAUTION: Risk of electric shock.

Bulletin No. PAXLRT-C
Drawing No. LP0562
Released 03/10

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

3.60 (91.4)

(44.5)

1.75

(96.5)

3.80

1.95

(49.5)

(2.5)

.10

(104.1)

4.10

(44.5)

1.75

PAR

9

1

3

2

4

5

6

7

8

10

8.8.8.8

C

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is

2.1" (53.4) H x 5" (127) W.

CC

US LISTED

US LISTED

UL

R

51EB

IND. CONT. EQ.