Specifications & dimensions 57 – Red Lion LEGEND User Manual
Page 61
14. CERTIFICATIONS AND COMPLIANCES:
SAFETY
IEC 6 1 0 1 0 -1 , EN 6 1 0 1 0 -1 : S a f e t y req u i remen t s f o r e l e c t ric a l
equipment for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Type 4X Indoor Enclosure rating (Face only), UL50
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge
EN 61000-4-2
Level 2; 4 Kv contact
Level 3; 8 Kv air
Electromagnetic RF fields
EN 61000-4-3
Level 3; 10 V/m
80 MHz - 1 GHz
Fast transients (burst)
EN 61000-4-4
Level 4; 2 Kv I/O
1
Level 3; 2 Kv power
RF conducted interference
EN 61000-4-6
Level 3; 10 V/rms
1
150 KHz - 80 MHz
Power
frequency magnetic fields
EN 61000-4-8
Level 4; 30 A/m
Emissions to EN 50081-2
RF interference
EN 55011
Enclosure class A
Power mains class A
Note:
1. When the unit is DC powered from terminal TBA pin 5 (common) and
terminal TBA pin 3 (DC OUT/IN) a power line filter was installed,
RLC #LFIL0000 or equivalent, so as not to impair the function of
the unit.
Refer to EMC Compliance Installation for additional information
15. CONSTRUCTION: High impact plastic case with clear viewing
window. This unit is rated for NEMA 4X/IP65 indoor use. Installation
Category II, Pollution Degree 2. Panel gasket and mounting clips included.
16. WEIGHT: 1.5 lbs. (0.68 Kg)
-59-